Status Register (address 0x1C)
The Status Register shows the overflow conditions of the timer and the integrator, and the locked status of the
Manchester Decoder. When the Status Register is read, the flags MAFx, TOx and IOx are reset.
Table 23
describes the Status Register.
AMC1210
SBAS372A–APRIL 2006–REVISED OCTOBER 2006
Table 23. Status Register
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
MAL4
MAL3
MAL2
MAL1
MAF4
MAF3
MAF2
MAF1
TO4
IO4
TO3
IO3
TO2
IO2
TO1
IO1
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
'0'
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
BIT POSITION
BIT
DESCRIPTION
15
MAL4
Manchester locked status for filter module 4.
0: The automatic Manchester encoder calibration is working properly
1: The automatic Manchester encoder calibration has not been able to perform a successful calibration
14
MAL3
Manchester locked status for filter module 3.
0: The automatic Manchester encoder calibration is working properly
1: The automatic Manchester encoder calibration has not been able to perform a successful calibration
13
MAL2
Manchester locked status for filter module 2.
0: The automatic Manchester encoder calibration is working properly
1: The automatic Manchester encoder calibration has not been able to perform a successful calibration
12
MAL1
Manchester locked status for filter module 1.
0: The automatic Manchester encoder calibration is working properly
1: The automatic Manchester encoder calibration has not been able to perform a successful calibration
11
MAF4
Manchester failure status for filter module 4.
0: The automatic Manchester encoder calibration has worked properly since last read access
1: The automatic Manchester encoder has detected problems since last read access
10
MAF3
Manchester failure status for filter module 3.
0: The automatic Manchester encoder calibration has worked properly since last read access
1: The automatic Manchester encoder has detected problems since last read access
9
MAF2
Manchester failure status for filter module 2.
0: The automatic Manchester encoder calibration has worked properly since last read access
1: The automatic Manchester encoder has detected problems since last read access
8
MAF1
Manchester failure status for filter module 1.
0: The automatic Manchester encoder calibration has worked properly since last read access
1: The automatic Manchester encoder has detected problems since last read access
7
TO4
Time counter overflow for filter module 4.
0: No overflow has occurred
1: An overflow occurred in the time measurement unit in filter module 4
6
IO4
Integrator overflow for filter module 4.
0: No overflow has occurred
1: An overflow occurred in the integrator unit in filter module 4
5
TO3
Time counter overflow for filter module 3.
0: No overflow has occurred
1: An overflow occurred in the time measurement unit in filter module 3
4
IO3
Integrator overflow for filter module 3.
0: No overflow has occurred
1: An overflow occurred in the integrator unit in filter module 3
3
TO2
Time counter overflow for filter module 2.
0: No overflow has occurred
1: An overflow occurred in the time measurement unit in filter module 2
2
IO2
Integrator overflow for filter module 2.
0: No overflow has occurred
1: An overflow occurred in the integrator unit in filter module 2
1
TO1
Time counter overflow for filter module 1.
0: No overflow has occurred
1: An overflow occurred in the time measurement unit in filter module 1
0
IO1
Integrator overflow for filter module 1.
0: No overflow has occurred
1: An overflow occurred in the integrator unit in filter module 1
34
Submit Documentation Feedback
相關(guān)PDF資料
PDF描述
AMC1210IRHAR Quad Digital Filter for 2nd-Order Delta-Sigma Modulator
AMC1210IRHARG4 Quad Digital Filter for 2nd-Order Delta-Sigma Modulator
AMC1210IRHAT Quad Digital Filter for 2nd-Order Delta-Sigma Modulator
AMC1210IRHATG4 Quad Digital Filter for 2nd-Order Delta-Sigma Modulator
AMC142SMA Industrial Control IC
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AMC1210EVM 功能描述:有源濾波器開(kāi)發(fā)工具 DATA CONVERTER RoHS:否 制造商:Maxim Integrated 產(chǎn)品:Evaluation Kits 工具用于評(píng)估:MAX7408-MAX7415, MAX7418-MAX7425 截止頻率:1 Hz to 15 kHz 工作電源電壓:3 V, 5 V
AMC1210IRHAR 功能描述:有源濾波器 4Ch Dig Filter RoHS:否 制造商:Maxim Integrated 通道數(shù)量:1 截止頻率:150 KHz 電源電壓-最大:11 V 電源電壓-最小:4.74 V 最大工作溫度:+ 85 C 安裝風(fēng)格:Through Hole 封裝 / 箱體:PDIP N 封裝:Tube
AMC1210IRHARG4 功能描述:有源濾波器 4Ch Dig Filter RoHS:否 制造商:Maxim Integrated 通道數(shù)量:1 截止頻率:150 KHz 電源電壓-最大:11 V 電源電壓-最小:4.74 V 最大工作溫度:+ 85 C 安裝風(fēng)格:Through Hole 封裝 / 箱體:PDIP N 封裝:Tube
AMC1210IRHAT 功能描述:有源濾波器 4 Ch Dig Filter for ADS120X RoHS:否 制造商:Maxim Integrated 通道數(shù)量:1 截止頻率:150 KHz 電源電壓-最大:11 V 電源電壓-最小:4.74 V 最大工作溫度:+ 85 C 安裝風(fēng)格:Through Hole 封裝 / 箱體:PDIP N 封裝:Tube
AMC1210IRHATG4 功能描述:有源濾波器 4Ch Dig Filter RoHS:否 制造商:Maxim Integrated 通道數(shù)量:1 截止頻率:150 KHz 電源電壓-最大:11 V 電源電壓-最小:4.74 V 最大工作溫度:+ 85 C 安裝風(fēng)格:Through Hole 封裝 / 箱體:PDIP N 封裝:Tube