Ericsson Internal
PRODUCT SPECIFICATION
4 (5)
Prepared (also subject responsible if other)
No.
EANDKUL
30/1301-BMR 453 Uen
Approved
Checked
Date
Rev
Reference
EAB/FJB/GMF (Natalie Johansson)
(MICJMAL)
2009-02-02
C
Thermal Consideration
General
The converters are designed to operate in different thermal
environments and sufficient cooling must be provided to
ensure reliable operation.
Cooling is achieved mainly by conduction, from the pins to the
host board, and convection, which is dependant on the airflow
across the converter. Increased airflow enhances the cooling
of the converter.
The Output Current Derating graph found in the Output section
for each model provides the available output current vs.
ambient air temperature and air velocity at Vin = 53 V.
The DC/DC converter is tested on a 254 x 254 mm,
35 m (1 oz), 8-layer test board mounted vertically in a wind
tunnel with a cross-section of 305 x 305 mm.
Proper cooling of the DC/DC converter can be verified by
measuring the temperature at position P1. The temperature at
these positions should not exceed the max values provided in
the table below.
Note that the max value is the absolute maximum rating
(non destruction) and that the electrical Output data is
guaranteed up to Tref +90°C.
See Design Note 019 for further information.
Position
Device
Designation
max value
P1
Pcb
Tref
125 C
P2
Opto-coupler
-
95 C
Top view
Bottom view
Definition of reference temperature (Tref)
The reference temperature is used to monitor the temperature
limits of the product. Temperatures above maximum Tref are
not allowed and may cause degradation or permanent damage
to the product. Tref is also used to define the temperature
range for normal operating conditions.
Tref is defined by the design and used to guarantee safety
margins, proper operation and high reliability of the module.
Connections (Top view)
Pin
Designation
Function
1
+In
Positive Input
2
RC
Remote Control
3
Case
Case to GND (optinal)
4
-In
Negative Input
5
-Out
Negative Output
6
S+
Positive Remote Sense
7
S-
Negative Remote Sense
8
SA0
Address pin 0
9
SA1
Address pin 1
10
SCL
PMBus Clock
11
SDA
PMBus Data
12
PG SYNC
Configurable I/O pin:
Power Good output, SYNC-,
tracking-, or ext ref-input
13
DGND
PMBus ground
14
SALERT
PMBus alert signal
15
CTRL CS
PMBus remote control
16
+Out
Positive Output
E
BMR 453
DC/DC Converters, Input 36-75V, Output 33A/400 W
EN/LZT 146 395 R1C February 2009
Ericsson AB
Technical Specication
15