Document Number: 71357
S-71155–Rev. C, 11-Jun-07
www.vishay.com
3
Vishay Siliconix
DG200B
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
SPECIFICATIONSa
Parameter
Symbol
Test Conditions
Unless Otherwise Specified
V+ = 15 V, V- = - 15 V
VIN = 2.4 V, 0.8 V
f
Tempb
Limits
- 40 to 85 °C
Unit
Minc
Typd
Maxc
Analog Switch
Analog Signal Rangee
VANALOG
Full
- 15
15
V
Drain-Source On-Resistance
rDS(on)
VD = ± 10 V, IS = - 1 mA
Room
Full
45
85
100
Ω
Source Off Leakage Current
IS(off)
VS = ± 14 V, VD = 14 V
Room
Full
- 2
- 100
± 0.01
2
100
nA
Drain Off Leakage Current
ID(off)
VD = ± 14 V, VS = 14 V
Room
Full
- 2
- 100
± 0.01
2
100
Channel On Leakage Currentf
ID(on)
VS = VD = ± 14 V
Room
Full
- 2
- 200
± 0.1
2
200
Digital Control
Input Current with
Input Voltage High
IINH
VIN = 2.4 V
Room
Full
- 0.5
- 1
0.0009
A
VIN = 15 V
Room
Full
0.005
0.5
1
Input Current with
Input Voltage Low
IINL
VIN = 0 V
Room
Full
- 0.5
- 1
- 0.0015
Dynamic Characteristics
Turn-On Time
tON
See Switching Time Test Circuit
Room
300
1000
ns
Turn-Off Time
tOFF
Room
200
425
Charge Injection
Q
CL = 1000 pF, Rg = 0 Ω, Vg = 0 V
Room
1
pC
Source Off Capacitance
CS(off)
f = 140 kHz
VIN = 5 V
VS = 0 V
Room
5
pF
Drain Off Capacitance
CD(off)
VD = 0 V
Room
5
Channel-On Capacitance
CD(on)+
CS(on)
VS = VD = 0 V, VIN = 0 V
Room
16
Off Isolation
OIRR
VIN = 5 V, RL = 75 Ω
VS = 2 V, f = 1 MHz
Room
90
dB
Crosstalk (Channel-to-Channel)
XTALK
Room
95
Power Supplies
Positive Supply Current
I+
Both Channels On or Off
VIN = 0 V and 5.0 V
Room
50
A
Negative Supply Current
I-
Room
- 10
±