Absolute Maximum Ratings
(Note 1)
Supply Voltage
Input Voltage
7V
5.5V
Operating Free Air Temperature Range
MIL
Storage Temperature Range
55C to +125C
65C to +150C
Recommended Operating Conditions
Symbol
Parameter
93L24 (MIL)
Nom
5
Units
Min
4.5
2
Max
5.5
V
CC
V
IH
V
IL
I
OH
I
OL
T
A
Note 1:
The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these
limits. The parametric values defined in the “Electrical Characteristics” table are not guaranteed at the absolute maximum ratings. The “Recommended Operating
Conditions” table will define the conditions for actual device operation.
Supply Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Output Current
Low Level Output Current
Free Air Operating Temperature
V
V
V
μA
mA
C
0.7
400
4.8
125
55
Electrical Characteristics
over recommended operating free air temperature (unless otherwise noted)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
(Note 2)
V
I
V
OH
Input Clamp Voltage
High Level Output Voltage
V
CC
= Min, I
I
= 10 mA
V
CC
= Min, I
OH
= Max,
V
IL
= Max, V
IH
= Min
V
CC
= Min, I
OL
= Max,
V
IH
= Min, V
IL
= Max
V
CC
= Max, V
I
= 5.5V
1.5
V
V
2.4
V
OL
Low Level Output Voltage
0.3
V
I
I
Input Current
@
Max
Input Voltage
High Level Input Current
Low Level Input Current
Short Circuit
Output Current
Supply Current
1
mA
I
IH
I
IL
I
OS
V
CC
= Max, V
I
= 2.4V
V
CC
= Max, V
I
= 0.3V
V
CC
= Max (Note 3)
40
0.8
25
μA
mA
mA
2.5
I
CC
V
CC
= Max
21
mA
Note 2:
All typicals are at V
CC
= 5V, T
A
= 25C.
Note 3:
Not more than one output should be shorted at a time, and the duration should not exceed one second.
Switching Characteristics
V
CC
= +5.0V, T
A
= +25C
Symbol
Parameter
C
L
= 15 pF
Units
Min
Max
32
35
54
75
70
77
100
102
t
PLH
t
PHL
t
PLH
t
PHL
t
PLH
t
PHL
t
PLH
t
PHL
Propagation Delay
E to A=B; E to A
<
B, A
>
B
Propagation Delay
An to A
>
B; Bn to A
>
B
Propagation Delay
An to A
<
B; Bn to A
<
B
Propagation Delay
An or Bn to A=B
ns
ns
ns
ns
www.fairchildsemi.com