1093 ThinTypeIonizerER-VW
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Static
Removers
Cleaning
Box
Pluse
Air-gun
Electrostatic
Sensor
ER-Q
ER-F
ER-TF
ER-VW
ER-V
Air supply monitoring function
This function causes discharging to stop automatically if the
supply of air drops below a certain pressure. Notification of
this is given when the AIR indicator lights and the discharge
output (DSC) turns off. This prevents objects which are not
charged from being overlooked when the air supply has
been stopped.
FUNCTIONS
The functions support accurate charge removal
In addition to the air supply monitoring function, the
ER-VW
is equipped with the following functions to ensure accurate
charge removal.
Discharge halt function
Check function
Abnormal discharge
monitoring function
Discharge output
Check output
Error output
: Uses external input to forcibly stop discharge.
: Uses the CHECK indicator and output to notify the
operator when it is time to clean or replace the
discharge needle.
: Uses the ERROR indicator and output to notify the
operator when a problem with discharge occurs,
and stops discharge. It can be canceled by means
of reset input.
: Output is ON during discharging. This lets you
check when discharging is being carried out.
: Output turns ON when the discharge needle is dirty.
: Output turns OFF when there is a problem with
discharging (normally it is ON). It also allows you to
check the power supply to the ionizer.
Discharge
DSC
Abnormal discharge
ERROR
Power supply
POWER
Discharge needle condition
CHECK
Air supply monitoring
AIR
Ionizer main unit One each of mating cable (length 0.5 m 1.640 ft), end connector and lead wire for connecting F.G. are supplied with the ionizer main unit.
Type
Appearance
Charge removal time
(±1,000 V → ±100 V)
Ion balance
Model No.
Spot
type
1 sec. or less (Note 1)
±10 V or less (Note 1)
ER-VW (Note 2)
Notes: 1) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25
MPa.(Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
2) The PNP output type is also available.
ORDER GUIDE
Connector attached cable
ER-VWCC□
Note: One connector attached cable (length 0.5 m 1.640 ft) is supplied with the ionizer main unit.
Please order it, if you need.
Type
Model No.
Description
Connector
attached cable
(Note)
ER-VWCC2
Length: 2 m 6.562 ft,
Net weight: 52 g approx.
0.15 mm2 8-core cabtyre cable with
connector
Cable outer diameter: 4.2 mm
0.165 in
ER-VWCC5
Length: 5 m 16.404 ft,
Net weight: 120 g approx.
ER-VWCC9
Length: 9 m 29.528 ft,
Net weight: 240 g approx.
Discharge needle
unit
ER-VWANT
Unit with replacement tungsten needles (2 needles per set)
Joint kit
ER-VWAR80
Connection cable (cable length 0.8 m 2.625 ft) and air tube
joint: 1 pc. each
Discharge needle unit
ER-VWANT
OPTIONS
New concept
Air supply
Discharge
Air supply
Discharge halt