Guide
Static
Removers
Cleaning
Box
Pluse
Air-gun
Electrostatic
Sensor
ER-Q
ER-F
ER-TF
ER-VW
ER-V
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
D1
[
+V]
[0 V]
[F.G.]
1
2
3
4
5
6
7
8
9
Tr1
Tr2
Tr3
5 V
4.7 k
D2
D3
8
5
4
3
2
1
7
6
50 mA max.
ZD1
ZD2
ZD3
50 mA max.
Load
Nozzle
Main
circuit
Joint connector (9-pin)
(Set the end connector, if not joint.)
Color code of connector attached cable
I/O connector of main unit (8-pin) terminal No.
(Brown) +V
(White) Discharge
output
(Black) Error output
(Orange) Check output
(Violet) Reset input
(Pink) Discharge halt input
+
–
*1
24 V DC
± 10 %
(Blue) 0 V
(Green / Yellow) F.G.
Internal circuit
Users’ circuit
Input signal condition
0.5 sec.
or more
Discharge
halt input
(Low input)
Open
Low
Reset input
(Rising input)
Open
Low
10 ms
or more
10 ms
or more
Discharge halt input
Reset input
Note: Repeated control using “Discharge halt input” input should be carried
out at 1 Hz or less.
Continuous discharging for 2 sec. or more is required for stable
sensing of check output.
If using with repeated control operations that include discharges of 2
sec. or less, use continuous discharges of 2 sec. or more to check the
check output when carrying out maintenance.
CHARGE REMOVAL CHARACTERISTICS (TYPICAL)
Measured using a 150 mm × 150 mm 5.906 in × 5.906 in CPM (charge plate monitor). (At center of CPM)
Air flow
Correlation between charge
removal distance and ion balance
Correlation between charge removal
distance and charge removal time
Charge removal field (0.50 MPa)
Connector terminal arrangement
Power & I/O connector
Joint connector
123456789
12345678
* 1
Non-voltage contact or NPN open-collector transistor
or
Discharge halt input
Low (0 V): Discharge halt
High (Open): Discharge (Operation starts)
Reset input
In the state that operation is stopped due to an error detection, open
0 V of the power supply from short-circuit state to cancel ERROR.
Symbols … D1: Reverse supply polarity protection diode
D2, D3: Input protection diode
ZD1, ZD2, ZD3 : Surge absorption zener diode
Tr1, Tr2, Tr3 : NPN output transistor
0
0.1
0.2
0.3
0.4
0.5
10
40
30
20
50
60
Air
flow
[/min.
(ANR)]
Applied pressure (MPa)
0.05 MPa
0.25 MPa
0.50 MPa
Ion
balance
(V)
0
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
–30
–20
–10
0
10
20
30
L
CPM
Ionizer
Charge removal distance L (mm in)
0
5
4
3
2
1
0.05 MPa
0.25 MPa
0.50 MPa
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
Charge removal distance L (mm in)
Charge
removal
time
(sec.)
L
CPM
Ionizer
0
0.5 sec.
1.0 sec.
2.0 sec.
5.0 sec.
W
CPM
Ionizer
L
100
3.937
200
7.874
300
11.811
400
15.748
500
19.685
Charge removal distance L (mm in)
Charge
removal
width
W
(mm
in)
200
7.874
100
3.397
0
100
3.397
150
5.906
50
1.969
50
1.969
150
5.906
200
7.874