14
Specifications HCS112MS
TABLE 2. AC ELECTRICAL PERFORMANCE CHARACTERISTICS
PARAMETER
SYMBOL
(NOTES 1, 2)
CONDITIONS
GROUP
A SUB-
GROUPS
TEMPERATURE
LIMITS
UNITS
MIN
MAX
PROPAGATION DELAY
CP to Q, Q
TPHL,
TPLH
VCC = 4.5V, VIH = 4.5V,
VIL = 0V
9
+25
o
C
2
28
ns
10, 11
+125
o
C, -55
o
C
2
35
ns
S to Q
TPHL
VCC = 4.5V, VIH = 4.5V,
VIL = 0V
9
+25
o
C
2
27
ns
10, 11
+125
o
C, -55
o
C
2
33
ns
S to Q
TPLH
VCC = 4.5V, VIH = 4.5V,
VIL = 0V
9
+25
o
C
2
27
ns
10, 11
+125
o
C, -55
o
C
2
33
ns
R to Q
TPHL
VCC = 4.5V, VIH = 4.5V,
VIL = 0V
9
+25
o
C
2
26
ns
10, 11
+125
o
C, -55
o
C
2
32
ns
R to Q
TPLH
VCC = 4.5V, VIH = 4.5V,
VIL = 0V
9
+25
o
C
2
26
ns
10, 11
+125
o
C, -55
o
C
2
32
ns
NOTES:
1. All voltages referenced to device GND.
2. AC measurements assume RL = 500
, CL = 50pF, Input TR = TF = 3ns, VIL = GND, VIH = VCC.
TABLE 3. ELECTRICAL PERFORMANCE CHARACTERISTICS
PARAMETER
SYMBOL
CONDITIONS
NOTES
TEMPERATURE
LIMITS
UNITS
MIN
MAX
Capacitance Power
Dissipation
CPD
VCC = 5.0V, VIH = 5.0V,
VIL = 0.0V, f = 1MHz
1
+25
o
C
-
15
pF
1
+125
o
C, -55
o
C
-
45
pF
Input Capacitance
CIN
VCC = 5.0V, VIH = 5.0V,
VIL = 0.0V, f = 1MHz
1
+25
o
C
-
10
pF
1
+125
o
C, -55
o
C
-
10
pF
Output Capacitance
COUT
VCC =5.0V, VIH = 5.0V,
VIL = 0.0V, f = 1MHz
1
+25
o
C
-
10
ns
1
+125
o
C, -55
o
C
-
10
ns
Pulse Width Time
CP, R, S
TW
VCC = 4.5V, VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
16
-
ns
1
+125
o
C, -55
o
C
24
-
ns
Setup Time J, K to
CP
TSU
VCC = 4.5V, VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
16
-
ns
1
+125
o
C, -55
o
C
24
-
ns
Hold Time J, K to CP
TH
VCC = 4.5V, VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
0
-
ns
1
+125
o
C, -55
o
C
0
-
ns
Removal Time
S to CP, R to CP
TREM
VCC = 4.5V, VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
16
-
ns
1
+125
o
C, -55
o
C
24
-
ns
Max Operating
Frequency
FMAX
VCC = 4.5V, VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
30
-
MHz
1
+125
o
C, -55
o
C
20
-
MHz
Output Transition
Time
TTHL,
TTLH
VCC = 4.5V , VIH = 4.5V,
VIL = 0.0V,
1
+25
o
C
1
15
ns
1
+125
o
C, -55
o
C
1
22
ns
NOTE:
1. The parameters listed in Table 3 are controlled via design or process parameters. Min and Max Limits are guaranteed but not directly
tested. These parameters are characterized upon initial design release and upon design changes which affect these characteristics.
Spec Number
518830