Hitachi Embedded Workshop User Manual
281
Format:
The method of defining each Action are as follows.
Stop
Input <filename> <addr> <size> <count>
Parameter
Type
Description
<filename>
Character
string
The name of the file from which data is input
<addr>
Numeric
Address to which the data is read.
<size>
Numeric
Size per data packet (1/2/4/8)
<count>
Numeric
Number of data packets (H’01 to H’FFFFFFFF)
Output <filename> <addr> <size> <count> [<option>]
Parameter
Type
Description
<filename>
Character
string
The name of the file to which data is saved
<addr>
Numeric
Address from which data is output
<size>
Numeric
Size per data packet (1/2/4/8)
<count>
Numeric
Number of data packets (H’01 to H’FFFFFFFF)
Keyword
Specifies a new file or appends to an existing file.
(optional, makes a new file when abbreviated.)
<option>
A
Adds the data to the existing file.
Interrupt <interrupt type1> [<priority>]
Parameter
Type
Description
<interrupt type1>
Numeric
Type of interrupt
Interrupt vector number (0 to H’FF)
<priority>
Numeric
Interrupt priority (optional, default = 0)
0 to 17
Examples:
BREAK_CYCLE 1000 20
Specifies breaks to occur H’20 times in every H’1000 cycles.
BCY 5000
Specifies a break to occur in every H’5000 cycles.