IDT54/74FCT388915T 70/100/133/150
3.3V LOW SKEW PLL-BASED CLOCK DRIVER
MILITARY AND COMMERCIAL TEMPERATURE RANGES
9.8
3
ABSOLUTE MAXIMUM RATINGS
(1)
CAPACITANCE
(T
A
= +25
°
C, f = 1.0MHz)
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: T
A
= 0
°
C to 70
°
C, V
CC
= 3.3V
±
0.3V
Symbol
V
IH
V
IL
I
I H
Parameter
Test Conditions
(1)
Min.
2.0
–0.5
—
Typ.
(2)
—
—
—
Max.
5.5
0.8
±
1
±
1
±
1
±
1
–1.2
—
—
—
Unit
V
V
μ
A
μ
A
μ
A
μ
A
mA
mA
V
Input HIGH Level
Input LOW Level
Input HIGH Current
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
V
CC
= Max.
V
I
= 5.5V
I
I L
I
OZH
I
OZL
Input LOW Current
High Impedance Output Current
(3-State Output Pins)
V
I
= GND
V
O
= V
CC
V
O
= GND
—
—
—
—
—
—
V
CC
= Max.
V
IK
I
ODH
I
ODL
V
OH
Clamp Diode Voltage
Output Drive Current
Output Drive Current
Output HIGH Voltage
V
CC
= Min., I
IN
= –18mA
V
CC
= Max., V
IN
= V
IH
or V
IL
, V
O
= 1.5V
(3)
V
CC
= Max., V
IN
= V
IH
or V
IL
, V
O
= 1.5V
(3)
V
CC
= Min.
—
–36
50
2.4
(5)
–0.7
—
—
3.0
I
OH
= –16mA
V
OL
V
H
I
CCL
I
CCH
I
CCZ
Output LOW Voltage
Input Hysteresis
Quiescent Power Supply Current
V
CC
= Min.
—
V
CC
= Max., V
IN
= GND or V
CC
(Test mode)
I
OL
= 32mA
—
—
—
0.3
100
2.0
0.5
—
4.0
V
mV
mA
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC
= 3.3V, +25
°
C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. This parameter is guaranteed but not tested.
5. V
OH
= V
CC
- 0.6V at rated current.
3052 tbl 04
3052 tbl 02
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RAT-
INGS may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating conditions for ex-
tended periods may affect reliability.
2. Vcc terminals.
3. Input terminals.
4. Output and I/O terminals.
Symbol
V
TERM(2)
Terminal Voltage
with Respect to
GND
V
TERM(3)
Terminal Voltage
with Respect to
GND
V
TERM(4)
Terminal Voltage
with Respect to
GND
T
A
Operating
Temperature
T
BIAS
Temperature
Under Bias
T
STG
Storage
Temperature
I
OUT
DC Output
Current
Rating
Commercial
–0.5 to +4.6
Military
–0.5 to +4.6
Unit
V
–0.5 to +7.0
–0.5 to +7.0
V
–0.5 to V
CC
+0.5
–0.5 to V
CC
+0.5
V
0 to +70
–55 to +125
°
C
–55 to +125
–65 to +135
°
C
–55 to +125
–65 to +150
°
C
–60 to +60 –60 to +60 mA
Symbol
C
IN
Parameter
(1)
Input
Capacitance
Output
Capacitance
Conditions
V
IN
= 0V
Typ.
4.5
Max.
6.0
Unit
pF
C
OUT
V
OUT
= 0V
5.5
8.0
pF
3052 lnk 03
NOTE:
1. This parameter is measured at characterization but not tested.