參數(shù)資料
型號: KSZ8041FTL TR
廠商: Micrel Inc
文件頁數(shù): 26/58頁
文件大?。?/td> 0K
描述: TXRX PHY 10/100 SGL LP 48TQFP
標(biāo)準(zhǔn)包裝: 1,000
類型: 收發(fā)器
驅(qū)動器/接收器數(shù): 1/1
規(guī)程: SMII
電源電壓: 3.135 V ~ 3.465 V
安裝類型: 表面貼裝
封裝/外殼: 48-TQFP
供應(yīng)商設(shè)備封裝: 48-TQFP(7x7)
包裝: 帶卷 (TR)
Micrel, Inc.
KSZ8041TL/FTL
April 2007
32
M9999-042707-1.1
100Base-FX Fiber Operation (KSZ8041FTL only)
100Base-FX fiber operation is similar to 100Base-TX copper operation with the differences being that the scrambler/de-
scrambler and MLT3 encoder/decoder are bypassed on transmission and reception. In addition, auto-negotiation is
bypassed, auto MDI/MDI-X is disabled, and speed is set to 100Mbps. The duplex can be set to either half or full. Usually,
it is set to full-duplex.
Fiber Signal Detect
In 100Base-FX operation, FXSD (fiber signal detect), input pin 48, is usually connected to the fiber transceiver SD (signal
detect) output pin. 100Base-FX mode is activated when the FXSD input pin is greater than 1V. When FXSD is between
1V and 1.8V, no fiber signal is detected and a Far-End Fault is generated. When FXSD is over 2.2V, the fiber signal is
detected.
100Base-FX mode and signal detection is summarized in the following table:
FXSD Input Voltage
Mode
Less than 0.2V
Copper mode
Greater than 1V, but less than 1.8V
Fiber mode
No signal detected
Far-End Fault generated (if enabled)
Greater than 2.2V
Fiber mode
Signal detected
Table 11. Copper and Fiber Mode Selection
To ensure proper operation, a resistive voltage divider is recommended to adjust the fiber transceiver SD (signal detect)
output voltage swing to match the FXSD pin’s input voltage threshold.
Alternatively, the Far-End Fault feature can be disabled. In this case, the FXSD input pin is tied high to 3.3V to force
100Base-FX mode.
Far-End Fault
A Far-End Fault (FEF) occurs when the signal detection is logically false on the receive side of the fiber transceiver. The
KSZ8041FTL detects a FEF when its FXSD input (pin 48) is between 1V and 1.8V. When a FEF is detected, the
KSZ8041FTL signals its fiber link partner that a FEF has occurred by transmitting a repetitive pattern of 84-ones and 1-
zero. This pattern is used to inform the fiber link partner that there is a faulty link on its transmit side.
By default, FEF is enabled. FEF is disabled by strapping “no FEF” (pin 43) low. See “Strapping Options” section for detail.
相關(guān)PDF資料
PDF描述
LTC2393CUK-16#TRPBF IC ADC 16BIT SER/PAR 1M 48-QFN
MS27473T18B35SC CONN PLUG 66POS STRAIGHT W/SCKT
IDT7201LA15TPI IC MEM FIFO 512X9 15NS 28-PDIP
MS3102R36-6P CONN RCPT 6POS BOX MNT W/PINS
IDT7201LA12TPG IC MEM FIFO 512X9 12NS 28-PDIP
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
KSZ8041MLL 功能描述:以太網(wǎng) IC 3.3V, 10Base-T/100Base-TX Physical Layer Transceiver with MII Support - Lead Free RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8041MLL TR 功能描述:以太網(wǎng) IC 3.3V, 10Base-T/100Base-TX Physical Layer Transceiver with MII Support - Lead Free RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8041MLLI 功能描述:以太網(wǎng) IC 3.3V, 10Base-T/100Base-TX Physical Layer Transceiver with MII support (Industrial grade, Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8041MLLI TR 功能描述:以太網(wǎng) IC 3.3V, 10Base-T/100Base-TX Physical Layer Transceiver with MII support (Industrial grade, Lead Free) RoHS:否 制造商:Micrel 產(chǎn)品:Ethernet Switches 收發(fā)器數(shù)量:2 數(shù)據(jù)速率:10 Mb/s, 100 Mb/s 電源電壓-最大:1.25 V, 3.45 V 電源電壓-最小:1.15 V, 3.15 V 最大工作溫度:+ 85 C 封裝 / 箱體:QFN-64 封裝:Tray
KSZ8041MNLU 制造商:MICREL 制造商全稱:Micrel Semiconductor 功能描述:10Base-T/100Base-TX Physical Layer Transceiver