Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
7/27
Table 4b: Output data double output modules
Output
(Outputs connected in Series)
LS 5320
24 V (2
×
12 V)
LS 5540
30 V (2
×
15 V)
LS 5660
48 V (2
×
24 V)
Characteristics
Conditions
min
typ
max
min
typ
max
min
typ
max
Unit
U
o
Output voltage
2
U
i nom
, I
o nom
24.0
30.0
48.0
V
U
op
Overvoltage protection
(supressor diode)
38
48
74
I
o nom
Output current
1
U
i min
...U
i max
T
C min
...T
C max
4.0
3.2
2.0
A
I
oL
Output current limit
4
U
i min
...U
i max
4.2
3.4
2.1
u
o 7
Output
voltage
noise
3
Low frequency U
i nom
, I
o nom
Switching freq.IEC/EN 61204
3
3
5
mV
pp
15
15
20
Total
BW = 20 MHz
100
100
150
D
U
o U
Static line regulation
U
i min
...U
i max
I
o nom
±
12
±
15
±
24
mV
D
U
o I
Static load regulation
U
i nom
, I
o
=
(0.1...1) I
o nom
40
60
96
u
o d 5
Dynamic Voltage
load
regulat.
U
i nom
, I
o
=
I
o nom
1
/
2
I
o nom
±
250
±
200
±
150
deviation
Recovery timeIEC/EN 61204
t
d 5
a
Uo
0.3
0.3
0.3
ms
Temperature coefficient U
i min
...U
i max
of output voltage
6
–
2.2
–
2.2
–
2.6
mV/K
0...I
o nom
1
If the output voltages are increased above U
o nom
through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that P
o nom
is not exceeded.
2
Series connection for U
o nom
= 24 V, 30 V or 48 V, see: R-Function for different output configurations.
3
Shortest possible wiring for series connection at the connector.
4
See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
5
See: Typical dynamic load regulation of U
o1
and U
o2.
6
Negative temperature coef
fi
cient (0...-3 mV/cell and K) available on request.
7
Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)