Cassette Style
100 Watt AC-DC Converters
S Series PFC
Edition 01/01.2001
8/27
Table 4c: Output data double output modules
Output
(Outputs independently loaded)
1
LS 5320
12 V/12 V
LS 5540
15 V/15 V
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min
typ
max
min
typ
max
min
typ
max
min
typ
max
Unit
U
o
Output voltage
U
i nom
, I
o nom 2
11.93
12.07 11.82
12.18 14.91
15.09 14.78
15.23
V
U
op
Overvoltage protection
(supressor diode)
19
19
24
24
I
o nom
Output current
3
U
i min
...U
i max
T
C min
...T
C max
4.0
4.0
3.2
3.2
A
I
oL
Output current limit
4
U
i min
...U
i max
4.2
4.2
3.4
3.4
u
o 8
Output
voltage
noise
Low frequency
U
i nom
, I
o nom
IEC/EN 61204
BW = 20 MHz
3
3
3
3
mV
pp
Switching freq.
12
12
10
10
Total
80
40
100
40
D
U
o U
Static line regulation
U
i min
...U
i nom
U
i nom
...U
i max
I
o nom
±
12
±
12
±
15
±
15
mV
D
U
o I
Static load regulation
U
i nom
, I
o
=
(0.1...1) I
o nom 5
48
5
60
5
u
o d 6
Dynamic Voltage
load
regulat.
U
i nom
, I
o
=
I
o nom
1
/
2
I
o nom
±
100
±
100
deviation
Recovery timeIEC/EN 61204
t
d 6
a
Uo
0.3
0.3
ms
Temperature coefficient U
i min
...U
i max
of output voltage
7
–
1.5
–
1.5
mV/K
0...I
o nom
Table 4d: Output data double output modules
Output
(Outputs independently loaded)
1
LS 5660
24 V/24 V
Characteristics
Conditions
Output 1
Output 2
min
typ
max
min
typ
max
Unit
U
o
Output voltage
U
i nom
, I
o nom 2
23.86
24.14 23.64
24.36
V
U
op
Overvoltage protection
(supressor diode)
37
37
I
o nom
Output current
3
U
i min
...U
i max
T
C min
...T
C max
2.0
2.0
A
I
oL
Output current limit
4
U
i min
...U
i max
2.1
2.1
u
o 8
Output
voltage
noise
Low frequency
U
i nom
, I
o nom
IEC/EN 61204
BW = 20 MHz
3
3
mV
pp
Switching freq.
10
10
Total
100
40
D
U
o U
Static line regulation
U
i min
...U
i nom
,
U
i nom
...U
i max
,
I
o nom
±
24
±
24
mV
D
U
o I
Static load regulation
U
i nom
, I
o
=
(0.1...1) I
o nom 5
96
5
u
o d 6
Dynamic Voltage
load
regulat.
U
i nom
, I
o
=
I
o nom
1
/
2
I
o nom
±
80
deviation
Recovery timeIEC/EN 61204
t
d 6
a
Uo
0.3
ms
Temperature coefficient U
i min
...U
i max
of output voltage
7
–
0.5
mV/K
0...I
o nom
1
Depending upon the desired out-
put configuration the wiring should
be made as shown in: R-Function
for different output configurations.
2
Same conditions for both outputs.
3
If the control voltages are in-
creased above U
o nom
via R-input
control, option Psetting, remote
sensing or option T, the output
currentsshould be reduced ac-
cordingly so that P
o nom
is not ex-
ceeded.
4
See: Output Voltage Regulation of
Single or Double Output Modules
with Outputs 1 and 2 Connected
in Series.
5
Condition for specified output.
Other output loaded with constant
current I
o
= I
o nom
. See: Output
voltage regulation of double out-
put units.
6
See: Typical dynamic load regula-
tion of U
o1
and U
o2
.
7
Negative temperature coefficient
(0....
–
3 mV/cell and K) available
on request.
8
Measured according to IEC/EN
61204 sub clause 3.10 with a
probe acc. to annex A of the same