參數(shù)資料
型號(hào): LUCL9215GAU-D
英文描述: Short-Loop Sine Wave Ringing SLIC
中文描述: 短回路正弦波振鈴用戶接口
文件頁(yè)數(shù): 25/50頁(yè)
文件大?。?/td> 1115K
代理商: LUCL9215GAU-D
Data Sheet
September 2001
Short-Loop Sine Wave Ringing SLIC
L9215A/G
Agere Systems Inc.
25
Applications
(continued)
dc Loop Current Limit
(continued)
Note that the overall current-limit accuracy achieved
will not only be affected by the specified accuracy of
the internal SLIC current-limit circuit (accuracy associ-
ated with the 67 term), but also by the accuracy of the
voltage source and the accuracy of any external resis-
tor divider network used and voltage offsets due to the
specified input bias current. Tolerance of the current
limit is ±8%. If a resistor divider from V
REF
is used, it is
recommended that the sum of the two resistors be
greater than 100 k
.
The above equations describe the active mode steady-
state current-limit response. There will be a transient
response of the current-limit circuit upon an on- to off-
hook transition. Typical active mode transient current-
limit response is given in Table 19.
Table 19. Typical Active Mode On- to Off-Hook Tip/
Ring Current-Limit Transient Response
Overhead Voltage
Active Mode
Overhead is programmable in the active mode via an
applied voltage source at the device’s OVH control
input. The voltage source may be an external voltage
source or derived via a resistor divider network from
the V
REF
SLIC output or an external voltage source. A
programmable external voltage source may be used to
provide software control of the overhead voltage. The
overhead voltage (V
OH
) is related to the OVH voltage
by:
V
OH
= 6.0 V + 5 * V
OVH
(V)
Overall accuracy is determined by the accuracy of the
voltage source and the accuracy of any external resis-
tor divider network used and voltage offsets due to the
specified input bias current. If a resistor divider from
V
REF
is used, a lower magnitude resistor will give a
more accurate result due to a lower offset associated
with the input bias current; however, lower value resis-
tors will also draw more power from V
REF
.
Note that a default overhead voltage of 6.0 V is
achieved by shorting input pin OVH to analog ground.
The default overhead provides sufficient headroom for
an on-hook transmission of a 3.14 dBm signal into
900
.
Overhead voltage may need to be increased to accom-
modate on-hook transmission of higher-voltage sig-
nals, such as meter pulse. The following example is
meant to illustrate the design procedure that can be fol-
lowed.
Assume we need on-hook transmission of a 1.0 Vrms
meter pulse into 200
. Further, assume 50
protec-
tion resistors are used.
V
OH
= 6.0 V + (1+ [2 * Rp]/200) * Vpeak
V
OH
= 6.0 + (1+ [2 * 50]/200) * 1 (1.414)
V
OH
= 8.121 V
Parameter
Value
I
LIM
+ 60
Unit
mA
dc Loop Current:
Active Mode
R
LOOP
= 100
On- to Off-hook
Transition t < 5 ms
dc Loop Current:
Active Mode
R
LOOP
= 100
On- to Off-hook
Transition t < 50 ms
dc Loop Current:
Active Mode
R
LOOP
= 100
On- to Off-hook
Transition t < 300 ms
I
LIM
+ 20
mA
I
LIM
mA
相關(guān)PDF資料
PDF描述
LUCL9215ARG-D Short-Loop Sine Wave Ringing SLIC
LUCL9215AAU-D GT 3C 3#0 PIN RECP WALL RM
LUCL9215AAU-DT GT 14C 12# 2#16 PIN RECP WALL
LUCL9216GGF-D Short-Loop Ringing SLIC with Ground Start
LUCL9216GGF-DT Short-Loop Ringing SLIC with Ground Start
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
LUCL9215GAU-DT 制造商:AGERE 制造商全稱:AGERE 功能描述:Short-Loop Sine Wave Ringing SLIC
LUCL9215GRG-D 制造商:AGERE 制造商全稱:AGERE 功能描述:Short-Loop Sine Wave Ringing SLIC
LUCL9216AGF-D 制造商:AGERE 制造商全稱:AGERE 功能描述:Short-Loop Ringing SLIC with Ground Start
LUCL9216AGF-DT 制造商:AGERE 制造商全稱:AGERE 功能描述:Short-Loop Ringing SLIC with Ground Start
LUCL9216ARG-D 制造商:AGERE 制造商全稱:AGERE 功能描述:Short-Loop Ringing SLIC with Ground Start