M902-01 Datasheet Rev 2.1
5
of 8
Revised 24Jun2004
Integrated Circuit Systems, Inc.
●
● www.icst.com
●
tel (508) 852-5400
M902-01
VCSO B
ASED
G
B
E C
LOCK
G
ENERATOR
P r o d u c t D a t a S h e e t
Integrated
Circuit
Systems, Inc.
PLL Simulator Tool Available
A free PC software utility is available on the ICS website
(www.icst.com). The M2000 Timing Modules PLL
Simulator is a downloadable application that simulates
PLL jitter and wander transfer characteristics. This
enables the user to set appropriate external loop
component values in a given application.
Refer to the SAW PLL Simulator Software web page at
www.icst.com/products/calculators/m2000filterSWdesc.htm
for additional information.
SAW PLL Application Notes Available
The ICS web site (www.icst.com) also has application
notes on:
PCB layout guidelines (including special detailed
instructions for preventing issues such as external
reference crosstalk)
Any new special device application details that may
become available
Instructions for using PLL simulator software
Guidelines for PCB fabrication (including recom-
mended PCB footprint, solder mask, and furnace
profile)
Refer to the SAW PLL Application Notes web page at
www.icst.com/products/appnotes/SawPllAppNotes.htm
for application notes and any additional product
information that may become available.
A
BSOLUTE
M
AXIMUM
R
ATINGS1
Symbol Parameter
V
I
Input Voltage
V
O
Output Voltage
I
O
Output Current
V
CC
Power Supply Voltage
T
S
Storage Temperature
Rating
-
0.5
to V
CC
+
0.5
-
0.5
to V
CC
+
0.5
Unit
V
V
25
mA
4.6
V
-
45
to +
100
o
C
Table 5: Absolute Maximum Ratings
Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the
device. These ratings are stress specifications only. Functional operation of product at these conditions
or any conditions beyond those listed in Recommended Conditions of Operation, DC Characteristics, or
AC Characteristics is not implied. Exposure to absolute maximum rating conditions for extended periods
may affect product reliability
.
R
ECOMMENDED
C
ONDITIONS
OF
O
PERATION
Symbol Parameter
V
CC
Positive Supply Voltage
T
A
Ambient Operating Temperature
Min
3.135
Typ
3.3
Max
3.465
Unit
V
Commercial
Industrial
0
+
70
+
85
o
C
o
C
-40
Table 6: Recommended Conditions of Operation