Multiple-Output Model Selection (Cont.)
– 80W Convection Cooled, 110W Forced-Air Cooled (200 LFM)
MODEL
OUTPUT
VOLTAGE
+5V
+12V
-5V
-12V
+5V
+12V
-12V
+24V
+5V
+12V
-15V
+15V
+12V
+24V
-12V
+5V
+3.3V
+5V
-12V
+12V
+3.3V
+5V
-5V
+12V
ADJUSTMENT
RANGE
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
4.75V to 5.25V
Fixed
Fixed
Fixed
11.55V to 12.45V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
3.2V to 3.4V
Fixed
Fixed
Fixed
CONVECTION COOLED
CURRENT (NOTE 1)
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
12A/20A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
12A/15A PK
5A/12A PK
1A/1.5A PK
1A/1.5A PK
FORCED AIR
CURRENT
12A/20A PK
5A/9A PK
1A/1.5A PK
3A/4A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
12A/20A PK
5A/9A PK
1A/1.5A PK
1A/1.5A PK
5A/9A PK
4A/4.5A PK
1A/1.5A PK
2A/2.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
15A/20A PK
8A/12A PK
1A/1.5A PK
1A/1.5A PK
LINE
LOAD
RIPPLE & NOISE
%p-p (NOTE 2)
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
0.5%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
1%
INITIAL SETTING
ACCURACY
5.09V to 5.11V
11.97V to 12.03V
-4.75V to -5.25V
-11.5V to -12.5V
5.09V to 5.11V
11.97V to 12.03V
-11.4V to -12.6V
23.2V to 24.8V
5.09V to 5.11V
11.97V to 12.03V
-14.4V to -15.6V
14.4V to 15.6V
11.96V to 12.03V
23.94V to 24.06V
-11.4V to -12.6V
4.75V to 5.25V
3.29V to 3.31V
4.98V to 5.02V
-11.4V to -12.6V
11.4V to 12.6V
3.29V to 3.31V
4.98V to 5.02V
-4.75V to -5.25V
11.4V to 12.6V
REGULATION
0.2%
0.1%
0.2%
0.3%
0.2%
0.1%
0.1%
0.1%
0.2%
0.1%
0.1%
0.1%
0.2%
0.2%
0.2%
0.2%
0.3%
0.2%
0.1%
0.1%
0.3%
0.2%
0.1%
0.1%
REGULATION
0.5%
2%
1.5%
8%
0.5%
1%
1%
1%
0.5%
1%
1%
1%
0.5%
1%
1%
1.5%
0.7%
1%
1%
1%
0.7%
1%
1%
1%
MAP110-4010
MAP110-4011
MAP110-4015
MAP110-4200
MAP110-4300
(Note 3)
MAP110-4305
(Note 3)
NOTES:
1) Peak loads up to 110 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 110 watts.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3) Sum of the output currents of V1 + V2 may not exceed 15 A continuous, 22 A peak.
Maximum Output Rtating:
MODEL/OUTPUT
OPTION
CONVECTION
CONTINUOUS/PEAK
FORCED AIR
200 LFM
MULTIPLE OUTPUT
BOARD ONLY
SINGLE OUTPUT
BOARD ONLY
MULTIPLE OUTPUT
‘L’-BRACKET
SINGLE OUTPUT
‘L’-BRACKET
MULTIPLE OUTPUT
‘C’-COVER
SINGLE OUTPUT
C’-COVER
80W/110W
90W/120W
80W/110W
90W/120W
60W/110W
65W/120W
110W
120W
110W
120W
110W
120W
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC input voltage (110 VAC)
MIN
85
47
85
40
20
NOM
MAX
264
63
UNITS
VAC
Hz
VAC
mS
50% load:
Full rated load:
Input Current
85 VAC (110W load).
110VAC (110W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264 VAC (one cycle). 25 °C.
Switching frequency of main transformer, (fixed frequency).
3.5
2.8
A
RMS
Input Protection
Inrush Surge Current
Operating Frequency
41
25
A
PK
kHz
20
MAP110 AC-DC Series Data Sheet
APR 04, 2006 revised to JUL 13, 2006
Page 2 of 5
www.power-one.com
Model numbers highlighted in yellow or shaded are not recommended for new designs.