MAX11800–MAX11803
Low-Power, Ultra-Small Resistive Touch-Screen
Controllers with I2C/SPI Interface
______________________________________________________________________________________
55
BIT
7
6
5
4
3
2
1
0
NAME
D_CV_A[3:0]
T_SAMPLE_A[1:0]
AVGA[1:0]
RESA
DEFAULT
0
BIT
NAME
DESCRIPTION
MAX11800/
MAX11801
MAX11802/
MAX11803
7:5
D_CV_A[3:0]
Delay initial auxiliary conversion
000: 10μs
001: 100μs
010: 500μs
011: 1ms
100: 5ms
101: 10ms
110: 50ms
111: 100ms
Yes
4:3
T_SAMPLE_A[1:0]
Sampling time for auxiliary measurements
00: 4 x (2MHz oscillator clock period) = 2μs
01: 16 x (2MHz oscillator clock period) = 8μs
10: 64 x (2MHz oscillator clock period) = 32μs
11: 256 x (2MHz oscillator clock period) = 128μs
Yes
2:1
AVGA[1:0]
Averaging sample depth for auxiliary measurements
If AVG_FLT = 0 (see the Operating Mode Configuration Register
(0x0B) section)
00: Single sample, no averaging
01: Take four samples, average two median samples
10: Take eight samples, average four median samples
11: Take 16 samples, average eight median samples
If AVG_FLT = 1 (see the Operating Mode Configuration Register
(0x0B) section)
00: Single sample, no averaging
01: Take four samples, average all samples
10: Take eight samples, average all samples
11: Take 16 samples, average all samples
Yes
0
RESA
Resolution for auxiliary measurements
0: 12-bit conversion (see the description of PWR_SAV in the
Measurement Resolution Configuration Register (0x02) section)
1: 8-bit conversion
Yes
Auxiliary Measurement Configuration Register (0x0A)
Note: A delimiter refers to the auxiliary input (AUX). Auxiliary measurements can only be requested in direct conversion modes.