MAX14821
IO-Link Device Transceiver
19
Maxim Integrated
Status Register [R1, R0] = [0,0]
Register Functionality
The device has four 8-bit-wide registers for configuration and monitoring (Table 1).
Table 1. Register Summary
R1/R0 = Register address.
REGISTER
R1
R0
D7
D6
D5
D4
D3
D2
D1
D0
Status
0
WuInt
DoFaultInt
DiLvl
QLvl
C/QFaultInt
UV33Int
UV24Int
OTempInt
CQConfig
0
1
RxFilter
HiSlew
C/Q_N/P
C/Q_PP
C/QDEn
Q
RxDis
C/QLoad
DIOConfig
1
0
DoInv
DoAv
DoN/P
DoPP
DoEn
DoBit
LiDis
DiLoad
Mode
1
RST
WuIntEn
DoFault
C/QFault
UV24
OTemp
UV33En
LDO33Dis
Bit
D7
D6
D5
D4
D3
D2
D1
D0
Bit Name
WuInt
DoFaultInt
DiLvl
QLvl
C/QFaultInt
UV33Int
UV24Int
OTempInt
Read/Write
R
POR State
0
X
0
Reset Upon Read
Yes
No
Yes
X = Unknown. These bits are dependent on the DI logic and C/Q inputs.
The Status register reflects the logic levels of C/Q and DI and shows the source of interrupts that cause an IRQ
hardware interrupt. The IRQ interrupt is asserted when an alarm condition (OTemp, UV33Int, UV24, C/QFault,
DoFault, WuInt) is detected. All bits in the Status register are read-only. The interrupt bits return to the default state
after the Status register is read. If a C/Q or DO fault condition persists, the associated interrupt bits are immediately
set after the Status register is read.
BIT
NAME
DESCRIPTION
D7
Wulnt
Wake-Up Interrupt Request. WuInt is set when an IO-Link wake-up request pulse is
detected on C/Q and the WuIntEn bit in the Mode register is set. IRQ asserts when
WuInt is set to 1. Read the Status register to clear the WuInt bit and deassert IRQ.
D6
DoFaultInt
DO Fault Interrupt. DoFaultInt interrupt bit and DoFault bit (in the Mode register) are
set when a fault condition occurs on the DO driver output. The device registers a fault
condition when a short circuit or voltage fault is detected on DO (see the DO Fault
Detection section for more information). IRQ asserts when DoFaultInt is 1. Read the
Status register to clear the DoFaultInt bit and deassert IRQ.
D5
DiLvl
DI Logic Level. The DiLvl bit mirrors the current logic level at the DI input. It is the
inverse of the LI output and is always active regardless of the state of the LiDis bit (Table
2). DiLvl does not affect IRQ. DiLvl is not changed when the Status register is read.
相關(guān)PDF資料
PDF描述
UVZ1C472MHD CAP ALUM 4700UF 16V 20% RADIAL
78Q2123-DB BOARD DEMO 78Q2123 78Q2133
78Q2120C09-DB BOARD DEMO 78Q2120C
NCP301LSN45T1G IC DETECTOR VOLTAGE 4.5V 5TSOP
MAX810TTRG IC MPU SUPERVISORY 3.08V SOT23
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MAX14821EVKIT# 功能描述:界面開發(fā)工具 MAX14820/21 EVAL KIT RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V
MAX14821EWA+ 制造商:Maxim Integrated Products 功能描述:- Rail/Tube
MAX14821EWA+T 功能描述:輸入/輸出控制器接口集成電路 100mA IO-Link Transceiver RoHS:否 制造商:Silicon Labs 產(chǎn)品: 輸入/輸出端數(shù)量: 工作電源電壓: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:QFN-64 封裝:Tray
MAX14824ETG+ 功能描述:輸入/輸出控制器接口集成電路 IO-Link Master Transceiver RoHS:否 制造商:Silicon Labs 產(chǎn)品: 輸入/輸出端數(shù)量: 工作電源電壓: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:QFN-64 封裝:Tray
MAX14824ETG+T 功能描述:輸入/輸出控制器接口集成電路 IO-Link Master Transceiver RoHS:否 制造商:Silicon Labs 產(chǎn)品: 輸入/輸出端數(shù)量: 工作電源電壓: 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:QFN-64 封裝:Tray