MB91265 Series
8
(Continued)
Pin no.
Pin
name
Circuit
type
Description
39
IC0
D
Trigger input terminal of input capture 0.
The port can serve as an input when set for input with the setting of the trigger input of
input capture 0. When the port is used for input capture input, this input is used as
required. The port output must therefore remain off unless intentionally used.
P25
General purpose input/output port.
This function becomes valid when trigger input of input capture 0 is set to disabled.
40
IC1
D
Trigger input terminal of input capture 1.
The port can serve as an input when set for input with the setting of the trigger input of
input capture 1. When the port is used for input capture input, this input is used as
required. The port output must therefore remain off unless intentionally used.
P26
General purpose input/output port.
This function becomes valid when trigger input of input capture 1 is set to disabled.
41
P27
D
General purpose input/output port.
42
PPG0
D
Output terminal of PPG timer 0.
This function becomes valid when output of PPG timer 0 is set to enabled.
PG1
General purpose input/output port.
This function becomes valid when output of PPG timer 0 is set to disabled.
43
MD2
H, K
Mode terminal 2.
Setting these pins determines the basic operation mode. Connect to VCC or VSS.
The circuit type of flash models is K.
44
MD1
H, K
Mode terminal 1.
Setting these pins determines the basic operation mode. Connect to VCC or VSS.
The circuit type of flash models is K.
45
MD0
H
Mode terminal 0.
Setting these pins determines the basic operation mode. Connect to VCC or VSS.
46
X0
A
Clock (oscillation) output terminal.
47
X1
A
Clock (oscillation) input terminal.
49
PPG4
D
Output terminal of PPG timer 4.
This function becomes valid when output of PPG timer 4 is set to enabled.
P37
General purpose input/output port.
This function becomes valid when output of PPG timer 4 is set to disabled.
50
INT7
E
External interrupt input terminal.
Since this input is used as required while the corresponding external interrupt is
enabled, the port output must remain off unless intentionally used.
PPG7
Output terminal of PPG timer 7.
This function becomes valid when output of PPG timer 7 is set to enabled.
P36
General purpose input/output port.
This function becomes valid when output of PPG timer 7 is set to disabled.
51
INIT
I
External reset input terminal.