Debug Support
Freescale Semiconductor
30-29
Command Sequence:
Figure 30-26. DUMP Command Sequence
Operand Data:
None
Result Data:
Requested data is returned as either a word or longword. Byte data is returned in
the least-significant byte of a word result. Word results return 16 bits of significant
data; longword results return 32 bits. A value of 0x0001 (with S set) is returned if
a bus error occurs.
30.5.3.3.6
Fill Memory Block (FILL)
A FILL command is used with the WRITE command to access large blocks of memory. An initial WRITE is
executed to set up the starting address of the block and to supply the first operand. The FILL command
writes subsequent operands. The initial address is incremented by the operand size (1, 2, or 4) and saved
in a temporary register after the memory write. Subsequent FILL commands use this address, perform the
write, increment it by the current operand size, and store the updated address in the temporary register.
If an initial WRITE is not executed preceding the first FILL command, the illegal command response is
returned.
NOTE
The FILL command does not check for a valid address—FILL is a valid
command only when preceded by another FILL, a NOP, or a WRITE command.
Otherwise, an illegal command response is returned. The NOP command can
be used for intercommand padding without corrupting the address pointer.
The size field is examined each time a FILL command is processed, allowing the operand size to be altered
dynamically.
Command Formats:
XXX
’NOT READY’
DUMP (B/W)
???
XXX
’ILLEGAL’
NEXT CMD
’NOT READY’
NEXT CMD
’NOT READY’
READ
MEMORY
LOCATION
XXX
BERR
NEXT CMD
RESULT
XXX
’NOT READY’
DUMP (LONG)
???
XXX
’ILLEGAL’
NEXT CMD
’NOT READY’
NEXT CMD
’NOT READY’
READ
MEMORY
LOCATION
XXX
BERR
NEXT CMD
MS RESULT
NEXT CMD
LS RESULT
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3