參數(shù)資料
型號: P1602AC
英文描述: MCU CMOS 18 LD LOW PWR, -40C to +85C, 18-SOIC 300mil, TUBE
中文描述: SIDAC的| 95V V(下公報)最大| 800mA的我(縣)|對220VAR
文件頁數(shù): 81/161頁
文件大?。?/td> 986K
代理商: P1602AC
SIDACtor
Data Book
GR 1089-Core
Teccor Electronics
(972) 580-7777
4 - 7
R
R
Another risk involved with power lines is indirect contact. Because of the large
magnetic fields created by the currents in the power lines, large voltages may be
induced upon the phone lines via electro-magnetic coupling. In this instance voltages
should be limited to 1000V
PK
and 600V
RMS
by the primary protectors, while the
current will be limited by the current carrying capacity of the 24 gauge wire.
First Level AC Power Fault Criteria
Test conditions for the First Level AC Power Fault Test are shown in Table 4-4. The
EUT is required to pass operationally.
Table 4-4 First Level AC Power Fault Test
Short Circuit
Current per
Conductor
(A)
.33
Notes:
1. For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the
indicated voltage(s) and repeated at a reduced voltage and current just below the operating threshold of the
secondary protectors.
2. Test 5 simulates a high impedance induction fault. For specific information, please contact Teccor
Electronics.
Second Level AC Power Fault Criteria
Test conditions for the Second Level AC Power Fault Test are dependent on whether
the EUT is intended for customer premises equipment or non-customer premises
equipment. In both instances, although the EUT is not required to pass operationally, it
may not become a fire, fragmentation, or electrical safety hazard.
Second Level AC Power Fault Criteria for Non-Customer Premises Equipment
For non-customer premises equipment, test conditions are shown in Table 4-5
(it should be noted that test conditions 1, 3, and 4 may be omitted if the EUT has
previously met UL 1459) and test connections are shown in Figure 4-1.
Test
Applied
Voltage, 60Hz
(V
RMS
)
Duration
Primary
Protectors
Test Connections
(Table 4-1,
Fig. 4-1)
1 (Note 1)
50
15 minutes
Removed
A
2 (Note 1)
100
.17
15 minutes
60 Applications,
1 Second Each
60 Applications,
1 Second Each
60 Applications,
5 Seconds Each
30s
Removed
A
3 (Note 1)
200, 400, 600
1A at 600V
Removed
A
4
1000
1
In Place
B
5 (Note 2)
N/A
N/A
Removed
N/A
6
600
0.5
Removed
A
7
600
2.2
2s
Removed
A
8
600
3
1s
Removed
A
9
1000
5
0.5
In Place
B
相關PDF資料
PDF描述
P1602ACRP MCU CMOS 18 LD LOW PWR, 0C to +70C, 18-SOIC 300mil, T/R
P1800SARP SIDAC|220V V(BO) MAX|800MA I(S)|DO-214AA
P1800SBRP SIDAC|220V V(BO) MAX|800MA I(S)|DO-214AA
P1800SCRP SIDAC|220V V(BO) MAX|800MA I(S)|DO-214AA
P1803AA SIDAC|210V V(BO) MAX|800MA I(S)|TO-220VAR
相關代理商/技術參數(shù)
參數(shù)描述
P1602AC MCL 功能描述:硅對稱二端開關元件 Modified TO-220 Two-Chip MicroCapacitance (MC) SIDACtor Device RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
P1602AC60 功能描述:硅對稱二端開關元件 500A 65/130V RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
P1602ACL 功能描述:硅對稱二端開關元件 65/130V 500A TO220A SIDACtor SYM 2Chp RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
P1602ACL60 功能描述:硅對稱二端開關元件 500A 65/130V RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA
P1602ACLRP 功能描述:硅對稱二端開關元件 500A 65/130V RoHS:否 制造商:Bourns 轉折電流 VBO:40 V 最大轉折電流 IBO:800 mA 不重復通態(tài)電流: 額定重復關閉狀態(tài)電壓 VDRM:25 V 關閉狀態(tài)漏泄電流(在 VDRM IDRM 下): 保持電流(Ih 最大值):50 mA 開啟狀態(tài)電壓:5 V 關閉狀態(tài)電容 CO:120 pF 最大工作溫度:+ 150 C 安裝風格:SMD/SMT 封裝 / 箱體:DO-214AA