PEF 81912/81913
Register Description
Data Sheet
188
2001-03-30
4.7.2
S_CONF2 - S-Transmitter Configuration Register 2
S_ CONF2
Value after reset: 80
H
read/write
Address:
32
H
4.7.3
S_STA - S-Transceiver Status Register
S_ STA
Value after reset: 00
H
read
Address:
33
H
Important: This register is used only if the Layer 1 state machine of the device is disabled
(S_CONF0:L1SW = 1) and implemented in software! With the layer 1 state machine
enabled, the signals from this register are automatically evaluated.
7
0
DIS_TX
0
0
0
0
0
0
0
DIS_TX
Disable Line Driver
0 =
Transmitter is enabled
1 =
Transmitter is disabled
7
0
RINF
0
ICV
0
FSYN
0
LD
RINF
Receiver INFO
00 =
01 =
10 =
11 =
Received INFO 0 (no signal)
Received any signal except INFO 0 or INFO 3
reserved
Received INFO 3
ICV
Illegal Code Violation
0 =
No illegal code violation is detected.
1 =
Illegal code violation (ANSI T1.605) in data stream is detected.