5.3. AT Command Set Description
AAnswer
The “A” command makes the modem go off-hook and
respond to an incoming call. This command is to be
executed after the Si2401 has indicated a ring has
occurred. (The Si2401 indicates an incoming ring by
echoing an “R”.)
This command is aborted if any other character is
transmitted to the Si2401 before the answer process is
completed.
Auto answer mode is entered by setting S00 (NR) to a
non-zero value. NR indicates the number of rings before
answering the line.
Upon
answering,
the
modem
communicates
by
whatever protocol has been determined via the modem
control registers in S07 (MF1).
If no transmit carrier signal is received from the calling
modem within the time specified in S39 (CDT), the
modem hangs up and enters the idle state.
DDial
DT#
Tone Dial Number.
DP#
Pulse Dial Number.
The D commands make the modem dial a telephone
call according to the digits and dial modifiers in the dial
string following the command. A maximum of 64 digits is
allowed. A DT command performs tone dialing, and a
DP command performs pulse dialing.
The ATH1 command can be used to go off-hook without
detecting a dial tone or dialing.
The dial string must contain only the digits “0–9”, “*”, “#”,
“A”, “B”, “C”, “D”, or the modifiers “;”, “/”, or “,”. Other
characters are interpreted incorrectly. The modifier “,
causes a two-second delay (added to the spacing value
in S04) in dialing. The modifier “/” causes a 125 ms
delay (added to the spacing value in S04) in dialing. The
modifier “;” returns the device to command mode after
dialing and must be the last character.
If any character is received by the Si2401 between the
ATDT#<CR> (or ATDP#<CR>) command and when the
connection is made (“c” or “d” is echoed), the extra
character is interpreted as an abort, and the Si2401
returns to command mode ready to accept AT
commands. A line feed character immediately following
the <CR> is treated as an “extra character” and aborts
the call.
If the modem does not have to dial (i.e., “ATDT<CR>” or
“ATDP<CR>” with no dial string), the Si2401 assumes
the call was manually established and attempts to make
a connection.
5.3.1. Automatic Tone/Pulse Dialing
The Si2401 can be configured to attempt DTMF dialing
and automatically revert to pulse dialing if it determines
that the line is not DTMF-capable. This feature is best
explained by the following example.
If it is desired that the telephone number, 12345, be
dialed, it is normally accomplished through either the
ATDT12345 or the ATDP12345 command. In the force
pulse dialing mode of operation, the following string
should be issued instead: ATDT1,p12345
If the result code returned is “t,”, this indicates that the
dialing was accomplished using DTMF dialing. If the
result code returned is “tt,”, it indicates that the dialing
was accomplished using pulse dialing.
In the above example, the Si2401 dials the first digit “1”
using DTMF dialing. The “,” is used to pause in order to
ensure that the central office has had time to accept the
DTMF digit “1”. When the Si2401 processes the “p”
command, it attempts to detect a dial tone. If a dial tone
is detected, the DTMF digit “1” was not effective; hence,
the line does not support DTMF dialing. Conversely, if
the dial tone is not detected, the DTMF digit “1” was
effective, and the line supports DTMF dialing. The
character after the “p” may or may not be dialed
depending on whether the DTMF digit “1” was effective.
If the “1” was effective (DTMF mode), the character after
the “p” is skipped. The next DTMF digit to be dialed is
“2”. Subsequent digits are all DTMF. If the “1” was not
effective, the first character after the “p” (the “1”) is
pulse-dialed, and subsequent digits are all pulse-dialed.
E
Command Mode Echo
Tells the Si2401 whether or not to echo characters sent
from the terminal.
EO
Does not echo characters sent from the terminal.
E1
Echoes characters sent from the terminal.
H0
Hangup
Hang up and go into command mode (go offline).
H1
Off-hook
Go off-hook and remain in command mode.
q#
Read S-Register in binary
V0
Result code with no carriage return
V1
Result code with added carriage
returns
Z
Software reset
z
Wakeup on ring
Table 12. AT Command Set Summary
相關(guān)PDF資料
PDF描述
UPA0J272MPD1TD CAP ALUM 2700UF 6.3V 20% RADIAL
UPA0J222MPD1TD CAP ALUM 2200UF 6.3V 20% RADIAL
GBC19DRAS CONN EDGECARD 38POS R/A .100 SLD
CM322522-2R2JL INDUCTOR CHIP 2.2UH 3225 SMD
RR70G821MDN1 CAP ALUM 820UF 4V 20% RADIAL
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
SI2401-FSR 功能描述:電信線路管理 IC 2400b/s System Side 3rd Gen DAA Tech RoHS:否 制造商:STMicroelectronics 產(chǎn)品:PHY 接口類型:UART 電源電壓-最大:18 V 電源電壓-最小:8 V 電源電流:30 mA 最大工作溫度:+ 85 C 最小工作溫度:- 40 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:VFQFPN-48 封裝:Tray
SI2401URT-EVB 功能描述:網(wǎng)絡(luò)開發(fā)工具 U 634-SI2401FS10-EVB RoHS:否 制造商:Rabbit Semiconductor 產(chǎn)品:Development Kits 類型:Ethernet to Wi-Fi Bridges 工具用于評估:RCM6600W 數(shù)據(jù)速率:20 Mbps, 40 Mbps 接口類型:802.11 b/g, Ethernet 工作電源電壓:3.3 V
SI2403 制造商:SILABS 制造商全稱:SILABS 功能描述:V.22BIS ISOMODEM CHIPSET WITH ERROR CORRECTION
SI2403-FT 制造商:Silicon Laboratories Inc 功能描述:MODEM CHIP CHIPSET ISOMODEM 2.4KBPS 24TSSOP - Rail/Tube
SI2404 制造商:未知廠家 制造商全稱:未知廠家 功能描述:V.90, V.34, V.32BIS, V.22BIS ISOMODEM?? WITH GLOBAL DAA