4
ECL Pro
SY100EP195V
Micrel, Inc.
M9999-120505
hbwhelp@micrel.com or (408) 955-1690
Absolute Maximum Ratings(1)
Supply Voltage (VCC)
PECL Mode (VEE=0V) ............................. –0.5V to +6.0V
Supply Voltage (VEE)
NECL Mode (VCC=0V) ............................ +0.5V to –6.0V
Any Input Voltage (VIN)
PECL Mode ....................................... –0.5V to VCC+0.5V
NECL Mode ....................................... +0.5V to VEE–0.5V
ECL Output Current (IOUT)
Continuous ............................................................. 50mA
Surge .................................................................... 100mA
IBB Sink/Source Current .......................................... ±0.5mA
Lead Temperature (soldering, 20 sec.) ................... +260°C
Storage Temperature (TS) ....................... –65°C to +150°C
ESD Rating(3) ........................................................... >1.5kV
Operating Ratings(2)
Supply Voltage (VCC)
PECL Mode (VEE=0V) ............................. +3.0V to +5.5V
Supply Voltage (VEE)
NECL Mode (VCC=0V) ............................ –3.0V to –5.5V
Ambient Temperature (TA) ......................... –40°C to +85°C
Package Thermal Resistance
TQFP-32 (θJA)
Still-air ............................................................. 50°C/W
500lfpm ............................................................ 42°C/W
TQFP-32 (θJC) ..................................................... 20°C/W
TA = –40°C to +85°C.
Symbol
Parameter
Condition
Min
Typ
Max
Units
VCC
Power Supply Voltage (PECL)
3.0
3.3
3.6
V
4.5
5.0
5.5
V
VEE
Power Supply Voltage (NECL)
–3.6
–3.3
–3.0
V
–5.5
–5.0
–4.5
V
IEE
Power Supply Current(4)
No load, over supply voltage
150
175
mA
Notes:
1. Permanent device damage may occur if absolute maximum ratings are exceeded. This is a stress rating only and functional operation is not implied
at conditions other than those detailed in the operational sections of this data sheet. Exposure to absolute maximum rating conditions for extended
periods may affect device reliability.
2. The data sheet limits are not guaranteed if the device is operated beyond the operating ratings.
3. Devices are ESD sensitive. Handling precautions recommended.
4. Required 500lfpm air flow when using +5V or –5V power supply.
DC ELECTRICAL CHARACTERISTICS