THS1060
10-BIT 60 MSPS IF SAMPLING COMMUNICATIONS
ANALOG-TO-DIGITAL CONVERTER
SLAS212A – MARCH 2000 – REVISED MARCH 2001
4
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
Supply voltage range: AVDD
– 0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DVDD
– 0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DRVDD
– 0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage between AVSS and DVSS
– 0.3 V to 0.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage between DRVDD and DVDD
– 0.5 V to 5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage between AVDD and DVDD
– 0.5 V to 5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital data output
– 0.3 V to DVDD+0.3 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CLK peak input current
20 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak total input current (all inputs)
– 30 mA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA: THS1060C
0
°C to 70°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
THS1060I
– 40
°C to 85°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range
– 65
°C to 150°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from the case for 10 seconds
260
°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
PARAMETER
MIN
NOM
MAX
UNIT
Sample rate
1
60
MSPS
Analog supply voltage, AVDD
4.75
5
5.25
V
Digital supply voltage, DVDD
4.75
5
5.25
V
Digital output driver supply voltage, DRVDD
3
3.3
5.25
V
CLK + high level input voltage, VIH
4
5
5.5
V
CLK + low-level input voltage, VIL
0
1
V
CLK – high-level input voltage, VIH
4
5
5.5
V
CLK – low-level input voltage, VIL
0
1
V
CLK pulse-width high, tp(H)
7.5
8.3
ns
CLK pulse-width low, tp(L)
7.5
8.3
ns
Operating free-air temperature range, TA
THS1060C
0
70
°C
Operating free-air temperature range, TA
THS1060I
– 40
85
°C
electrical characteristics, over recommended operating free-air temperature range,
AVDD = DVDD = 5 V, DRVDD = 3.3 V, internal references, CLK = 60 MHz (unless otherwise noted)
dc accuracy
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
DNL
Differential nonlinearity (see Note 1)
±0.4
±1
LSB
No missing codes (see Note 2)
Assured
INL
Integral nonlinearity (see Note 1)
±0.9
±3
LSB
EO
Offset error
15
31
mV
EG
Gain error
– 7
– 10
%FSR
All typical values are at TA = 25°C.
NOTES:
1. Tested without over ranging
2. Tested with over ranging