TSL230RLF, TSL230ARLF, TSL230BRLF
PROGRAMMABLE LIGHT-TO-FREQUENCY CONVERTERS
TAOS079A
OCTOBER 2006
2
Copyright 2006, TAOS Inc.
The
LUMENOLOGY
Company
www.taosinc.com
Terminal Functions
TERMINAL
NAME
GND
OE
OUT
S0, S1
S2, S3
V
DD
TYPE
DESCRIPTION
NO.
4
3
6
1, 2
7, 8
5
Ground
Enable for f
O
(active low)
Scaled-frequency (f
O
) output
Sensitivity-select inputs
f
O
scaling-select inputs
Supply voltage
I
O
I
I
Selectable Options
S1
L
S0
L
SENSITIVITY
Power down
S3
L
L
H
H
S2
L
H
L
H
f
O
SCALING (divide-by)
1
2
10
100
L
H
H
H
L
H
1
×
10
×
100
×
Available Options
DEVICE
TSL230R
LF
TSL230AR
LF
TSL230BR
LF
T
A
PACKAGE
LEADS
PDIP
8
PDIP
8
PDIP
8
PACKAGE DESIGNATOR
P
P
P
ORDERING NUMBER
TSL230RP
LF
TSL230ARP
LF
TSL230BRP
LF
25
°
C to 70
°
C
25
°
C to 70
°
C
25
°
C to 70
°
C
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
DD
(see Note 1)
Input voltage range, all inputs, V
I
Operating free-air temperature range, T
A
Storage temperature range
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
6 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.3 V to V
DD
+ 0.3 V
25
°
C to 70
°
C
25
°
C to 85
°
C
260
°
C
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Not recommended for solder reflow.
NOTE 1: All voltage values are with respect to GND.
Recommended Operating Conditions
MIN
2.7
NOM
MAX
5.5
V
DD
0.8
UNIT
V
V
V
°
C
Supply voltage, V
DD
High-level input voltage, V
IH
Low-level input voltage, V
IL
Operating free-air temperature range, T
A
5
V
DD
= 4.5 V to 5.5 V
V
DD
= 4.5 V to 5.5 V
2
0
25
70