TSL230RLF, TSL230ARLF, TSL230BRLF
PROGRAMMABLE LIGHT-TO-FREQUENCY CONVERTERS
TAOS079A
OCTOBER 2006
3
The
LUMENOLOGY
Company
Copyright 2006, TAOS Inc.
www.taosinc.com
Electrical Characteristics at T
A
= 25
°
C, V
DD
= 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
I
OH
=
4 mA
I
OL
= 4 mA
MIN
TYP
4.5
0.25
MAX
UNIT
V
V
μ
A
μ
A
mA
μ
A
MHz
ppm/
°
C
%/V
V
OH
V
OL
I
IH
I
IL
High-level output voltage
Low-level output voltage
High-level input current
Low-level input current
4
0.4
5
5
3
I
DD
Supply current
Power-on mode
Power-down mode
2
5
12
F.S.
Full-scale frequency
Temperature coefficient of output frequency
Supply voltage sensitivity
Full-scale frequency is the maximum operating frequency of the device without saturation.
1.1
λ
≤
700 nm
V
DD
= 5 V
±
10%
±
150
±
0.5
k
SVS
Operating Characteristics at V
DD
= 5 V, T
A
= 25
°
C, E
e
= 130
μ
W/cm
2
,
λ
p
= 640 nm (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TSL230R
LF
MIN
TSL230AR
LF
MIN
TSL230BR
LF
MIN
UNIT
TYP
MAX
TYP
MAX
TYP
MAX
S0 = S1 = H,
S2 = S3 = L
80
100
120
90
100
110
95
100
105
kHz
S1 = H,
S0 = S2 = S3 = L
S0 = H,
S1 = S2 = S3 = L
8
10
12
9
10
11
9.5
10
10.5
kHz
0.8
1
1.2
0.9
1
1.1
0.95
1
1.05
kHz
f
O
Output frequency
S0 = S1 = S2 = H,
S3 = L
S0 = S1 = S3 = H,
S2 = L
40
50
60
45
50
55
47.5
50
52.5
kHz
8
10
12
9
10
11
9.5
10
10.5
kHz
S0 = S1 = S2 = S3 = H
E
e
= 0,
S0 = S1 = H,
S2 = S3 = L
0.8
1
1.2
0.9
1
1.1
0.95
1
1.05
kHz
0.4
10
0.4
10
0.4
10
Hz
R
e
Responsivity
S0 = S1 = H,
S2 = S3 = L
0.77
0.77
0.77
kHz/
(μ
W/
cm
2
)
ns
s
%F.S.
%F.S.
%F.S.
t
w
Output pulse
duration
S2 = S3 = L
S2 or S3 = H
f
O
= 0 MHz to 10 kHz
f
O
= 0 MHz to 100 kHz
f
O
= 0 MHz to 1 MHz
125
600
125
600
125
600
1/2f
O
±
0.1%
±
0.2%
±
0.5%
1/2f
O
±
0.1%
±
0.2%
±
0.5%
1/2f
O
±
0.1%
±
0.2%
±
0.5%
#
Nonlinearity
Recovery from
power down
Step response to
full-scale step input
Response time to
programming
change
100
100
100
μ
s
1 pulse of new frequency plus 1
μ
s
2 periods of new principal frequency
plus 1
μ
s
§
Response time to
output enable (OE)
Nonlinearity is defined as the deviation of f
O
from a straight line between zero and full scale, expressed as a percent of full scale.
#
Nonlinearity test condition: S0 = S1 = H, S2 = S3 = L.
§
Principal frequency is the internal oscillator frequency, equivalent to divide-by-1 output selection.
50
150
50
150
50
150
ns