SGLS245 MAY 2004
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
Ordering Information
UCC2
0
Q
PACKAGE
D
= Plastic SOIC
PRODUCT OPTION
0 through 5
AUTOMOTIVE TEMPERATURE RANGE INDICATOR
D
TAPE and REEL INDICATOR
R
813-
Q1
Q100 INDICATOR
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
V
CC
voltage
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V
CC
current
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output energy, (Capacitive Load)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analog Inputs (FB, CS)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Dissipation at T
A
< +25 C (D package)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds
12 V
30 mA
±
1 A
20
μ
J
0.3 V to 6.3 V
0.65 W
65 C to 150 C
300 C
. . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Unless otherwise indicated, voltages are reference to ground and currents are positive into and negative out of the specified terminals.
In normal operation VCC is powered through a current limiting resistor. Absolute maximum of 12 V applies when VCC is driven from a low
impedance source such that ICC does not exceed 30 mA (which includes gate drive current requirement).
electrical characteristics
T
A
= 40 C to 125 C, V
CC
= 10 V (see Note 1), RT = 100 k
from REF to
RC, CT = 330 pF from RC to GND, 0.1-F capacitor from V
CC
to GND, 0.1-F capacitor from V
REF
to
GND and T
A
= T
J
(unless otherwise stated)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Reference Section
Output voltage
TJ = 25 C, I = 0.2 mA
UCC2813-0/1/2/4
4.925
5
5.075
V
UCC2813-3/5
3.94
4
4.06
Load regulation voltage
I = 0.2 mA to 5 mA
10
30
mV
Total variation voltage
See Note 5
UCC2813-0/1/2/4
4.84
5
5.1
V
UCC2813-3/5
3.84
4
4.08
Output noise voltage
f = 10 Hz to 10 kHz,
See Note 7
TJ = 25 C
70
μ
V
Long term stability
1000 hours,
See Note 7
TA = 125 C
5
mV
Output short-circuit current
5
35
mA