4
V61C31161024 Rev. 0.5 August 1999
MOSEL V ITELIC
V61C31161024
DC Electrical Characteristics
(over all temperature ranges, V
CC
= 3.3V
±
10%)
NOTES:
1.
2.
3.
4.
These are absolute values with respect to device ground and all overshoots due to system or tester noise are included.
V
IL
(Min.) = -3.0V for pulse width < 20ns.
f
MAX
= 1/t
RC
.
Maximum values.
Symbol Parameter
Test Conditions
-10
-12
-15
Units
Min.
Max.
Min.
Max.
Min.
Max.
I
IL
Input Leakage Current
V
CC
= MAX, V
IN
= GND to V
CC
—
5
—
5
—
5
μ
A
I
OL
Output Leakage Current
CE = V
V
OUT
IH
, V
CC
= Max,
= GND to V
CC
—
5
—
5
—
5
μ
A
I
CC
Operating Power Supply
Current
CE = V
IL
, I
OUT
= 0, f = f
max
—
140
—
130
—
120
mA
ISB
Standby Power Supply
Current (TTL Level)
CE = V
IH
, f = f
max
—
25
—
20
—
20
mA
I
SB1
Standby Power Supply
Current (CMOS Level)
CE
or V
≥
V
> V
CC
– 0.2V, f = 0, V
– 0.2V
IN
≤
0.2V
IN
CC
—
2
—
2
—
2
mA
V
IL
Input Low Voltage
(1,2)
-0.3
0.8
-0.3
0.8
-0.3
0.8
V
V
IH
Input High Voltage
(1)
2.2 V
CC
+ 0.3 2.2
V
CC
+ 0.3
2.2 V
CC
+ 0.3
V
V
OL
Output Low Voltage
I
OL
= 4mA
—
0.4
—
0.4
—
0.4
V
V
OH
Output High Voltage
I
OH
= -2mA
2.4
—
2.4
—
2.4
—
V
AC Test Conditions
Key to Switching Waveforms
AC Test Loads and Waveforms
Input Pulse Levels
0 to 3V
Input Rise and Fall Times
3 ns
Timing Reference Levels
1.5V
Output Load
see below
WAVEFORM
INPUTS
OUTPUTS
MUST BE
STEADY
WILL BE
STEADY
MAY CHANGE
FROM H TO L
WILL BE
CHANGING
FROM H TO L
MAY CHANGE
FROM L TO H
WILL BE
CHANGING
FROM L TO H
DON'T CARE:
ANY CHANGE
PERMITTED
CHANGING:
STATE
UNKNOWN
DOES NOT
APPLY
CENTER
LINE IS HIGH
IMPEDANCE
“OFF” STATE
+3.3V
480
255
I/O Pins
C
L
= 30 pF*
+3.3V
480
255
* Includes scope and jig capacitance
I/O Pins
for t
CLZ
, t
CHZ
, t
OLZ
, t
WHZ
, t
OW
, and t
OHZ
C
L
= 5pF*
6131161024-05