參數(shù)資料
型號(hào): X9269
元件分類: 數(shù)字電位計(jì)
英文描述: Dual Digitally-Controlled Potentiometers
中文描述: 雙數(shù)字控制電位器
文件頁(yè)數(shù): 9/25頁(yè)
文件大?。?/td> 422K
代理商: X9269
X9269
REV 1.1.11 2/17/03
Characteristics subject to change without notice.
9 of 25
www.xicor.com
DEVICE DESCRIPTION
Wiper Counter Register (WCR)
The X9269 contains two Wiper Counter Registers, one
for each DCP potentiometer. The Wiper Counter
Register can be envisioned as a 8-bit parallel and
serial load counter with its outputs decoded to select
one of 256 switches along its resistor array. The
contents of the WCR can be altered in four ways: it
may be written directly by the host via the Write Wiper
Counter Register instruction (serial load); it may be
written indirectly by transferring the contents of one of
four associated data registers via the XFR Data
Register instruction (parallel load); it can be modified
one step at a time by the Increment/Decrement
instruction (see Instruction section for more details).
Finally, it is loaded with the contents of its Data
Register zero (DR0) upon power-up.
The Wiper Counter Register is a volatile register; that
is, its contents are lost when the X9269 is powered-
down. Although the register is automatically loaded
with the value in DR0 upon power-up, this may be
different from the value present at power-down. Power-
up guidelines are recommended to ensure proper
loadings of the DR0 value into the WCR (See Design
Considerations Section).
Data Registers (DR)
Each potentiometer has four 8-bit nonvolatile Data
Registers. These can be read or written directly by the
host. Data can also be transferred between any of the
four Data Registers and the associated Wiper Counter
Register. All operations changing data in one of the
data registers is a nonvolatile operation and will take a
maximum of 10ms.
If the application does not require storage of multiple
settings for the potentiometer, the Data Registers can
be used as regular memory locations for system
parameters or user preference data.
Bit [7:0] are used to store one of the 256 wiper
positions (0~255).
Table 1. Wiper counter Register, WCR (8-bit), WCR[7:0]:
Used to store the current wiper position (Volatile, V).
Table 2. Data Register, DR (8-bit), Bit [7:0]:
Used to store wiper positions or data (Nonvolatile, NV).
Bit 7
Bit 6
Bit 5
Bit 4
NV
NV
NV
NV
MSB
WCR7
V
(MSB)
WCR6
V
WCR5
V
WCR4
V
WCR3
V
WCR2
V
WCR1
V
WCR0
V
(LSB)
Bit 3
NV
Bit 2
NV
Bit 1
NV
Bit 0
NV
LSB
相關(guān)PDF資料
PDF描述
X9269TS24 Single Supply/Low Power/256-Tap/2-Wire Bus
X9269TS24-2.7 Single Supply/Low Power/256-Tap/2-Wire Bus
X9269TV24 Single Supply/Low Power/256-Tap/2-Wire Bus
X9269UV24 Single Supply/Low Power/256-Tap/2-Wire Bus
X9269UV24-2.7 Single Supply/Low Power/256-Tap/2-Wire Bus
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
X9269_07 制造商:INTERSIL 制造商全稱:Intersil Corporation 功能描述:Dual Digitally-Controlled Potentiometers
X9269TB16 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Dual Digitally-Controlled Potentiometers
X9269TB16-2.7 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Dual Digitally-Controlled Potentiometers
X9269TB16I 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Dual Digitally-Controlled Potentiometers
X9269TB16I-2.7 制造商:XICOR 制造商全稱:Xicor Inc. 功能描述:Dual Digitally-Controlled Potentiometers