á
PRELIMINARY
SIX CHANNEL DS3/E3 FRAMER IC WITH HDLC CONTROLLER
XRT72L56
REV. P1.1.2
72
this bit-field to "0" does disable all Receive Section related
Interrupts.
Bit 1 - TxDS3/E3 Interrupt Enable
This Read/Write bit-field permits the user to enable or
disable all Transmit Section related interrupts (within
the XRT72L56), at the Block Level.
Setting this bit-field to "0" disables all Transmit Sec-
tion related Interrupts within the XRT72L56.
Setting this bit-field to "1" enables the Transmit Sec-
tion related Interrupts (within the XRT72L56) at the
block level.
N
OTE
:
Setting this bit-field to "1" does not enable all Trans-
mit Section related Interrupts. Each of these interrupts can
still be disabled at the Source Level. However, setting this
bit-field to "0" does disable all Transmit Section related
Interrupts.
Bit 0 - One-Second Interrupt Enable
This Read/Write bit-field permits the user to enable or
disable the One-Second Interrupt, within the
XRT72L56. If this interrupt is enabled, then the
XRT72L56 will generate interrupts to the μC/μP at
one-second intervals.
Setting this bit-field to "0" disables the One-Second
Interrupt. Conversely, setting this bit-field to "1" en-
ables the One-Second Interrupt.
2.4.2.6
Block Interrupt Status Register
Bit 7 - RxDS3/E3 Interrupt Status Indicator
This Read-Only bit-field indicates whether or not a
Receive-Section related interrupt has been requested
and is awaiting service.
If this bit-field is set to "0", then there are no Receive-
Section related interrupts awaiting service. Con-
versely, if this bit-field is set to "1", then there is at
least one Receive Section related interrupt, awaiting
service.
N
OTE
:
If this bit-field is set to "1", then the
μC/μP
must
read the Source-Level Interrupt Status register, in order to
clear this bit-field.
Bit 1 - TxDS3/E3 Interrupt Status Indicator
This Read-Only bit-field indicates whether or not a
Transmit-Section related interrupt has been request-
ed and is awaiting service.
If this bit-field is set to "0", then there are no Transmit-
Section related interrupts awaiting service. Con-
versely, if this bit-field is set to "1", then there is at
least one Transmit Section related interrupt, awaiting
service.
N
OTE
:
If this bit-field is set to "1", then the
μC/μP
must
read the Source-Level Interrupt Status register, in order to
clear this bit-field.
Bit 0 - One-Second Interrupt Status
This Reset-upon-Read bit field indicates whether or
not a One-Second interrupt has been requested and
is awaiting service.
If this bit-field is set to "0", then the One-Second inter-
rupt is not awaiting service. Conversely, if this bit-
field is set to "1", then the One-Second interrupt is
awaiting service.
N
OTE
:
This bit-field will be cleared immediately after the
μC/μP
has read this register.
BLOCK INTERRUPT STATUS REGISTER (ADDRESS = 0X05)
B
IT
7
B
IT
6
B
IT
5
B
IT
4
B
IT
3
B
IT
2
B
IT
1
B
IT
0
RxDS3/E3
Interrupt
Status
Not Used
TxDS3/E3
Interrupt
Status
One-Second
Interrupt
Status
RO
RO
RO
RO
RO
RO
RO
RUR
0
0
0
0
0
0
0
0