Absolute Maximum Ratings
(Note 1)
Supply Voltage
Input Voltage
Operating Free Air Temperature Range
7V
5.5V
Military
Commercial
Storage Temperature Range
55C to +125C
0C to +70C
65C to +150C
Recommended Operating Conditions
Symbol
Parameter
Military
Nom
5
Commercial
Nom
5
Units
Min
4.5
2
Max
5.5
Min
4.75
2
Max
5.25
V
CC
V
IH
V
IL
I
OH
I
OL
T
A
t
s
(H)
t
s
(L)
t
h
(H)
t
h
(L)
t
w
(H)
t
w
(L)
t
w
(L)
t
w
(L)
t
rec
Note 1:
The “Absolute Maximum Ratings” are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these
limits. The parametric values defined in the “Electrical Characteristics” table are not guaranteed at the absolute maximum ratings. The “Recommended Operating
Conditions” table will define the conditions for actual device operation.
Supply Voltage
High Level Input Voltage
Low Level Input Voltage
High Level Output Current
Low Level Output Current
Free Air Operating Temperature
Setup Time HIGH or LOW
D
n
to CP
Hold Time HIGH or LOW
D
n
to CP
Clock Pulse Width HIGH
or LOW
MR Pulse Width with CP HIGH
MR Pulse Width with CP LOW
Recovery Time MR to CP
V
V
V
0.8
0.4
16
125
0.8
0.4
16
70
mA
mA
C
ns
55
20
20
0
0
25
25
30
40
33
0
20
20
0
0
25
25
30
40
33
ns
ns
ns
ns
ns
Electrical Characteristics
Over Recommended Operating Free Air Temperature Range (Unless Otherwise Noted)
Symbol
Parameter
Conditions
Min
Typ
Max
Units
(Note 2)
V
I
V
OH
Input Clamp Voltage
High Level Output Voltage
V
CC
= Min, I
I
= 12 mA
V
CC
= Min, I
OH
= Max
V
IL
= Max
V
CC
= Min, I
OL
= Max
V
IH
= Min
V
CC
= Max, V
I
= 5.5V
V
CC
= Max, V
I
= 2.4V
MR, D
n
Inputs
CP Inputs
S Inputs
CP (COM) Inputs
V
CC
= Max, V
I
= 0.4V
MR, D
n
Inputs
CP Inputs
S Inputs
CP (COM) Input
1.5
V
V
2.4
3.4
V
OL
Low Level Output Voltage
0.2
0.4
V
I
I
I
IH
Input Current
@
Max Input Voltage
High Level Input Current
1
40
mA
60
80
120
1.6
μA
I
IL
Low Level Input Current
2.4
3.2
4.8
mA
www.fairchildsemi.com