PRODUCT SPECIFICATION
FMS2704/FMS2704L
10
REV. 1.01 12/2/99
Note: An error that causes continuous interrupts may be concealed using the mask register, until the error can be alleviated.
2
FAULT_D2
R
Remote Diode 2 Fault.
0: Diode functional
1: Short or open circuit.
4–3
R
Reserved
5
RTV1
R
Remote Diode 1 Temperature Violation.
0: Remote temperature within limits.
1: Remote temperature limit violated
6
THERM
R
THERM input status.
0: THERM input negated.
1: THERM input asserted.
7
FAULT_D1
R
Remote Diode 1 Fault.
0: Diode functional
1: Short or open circuit.
Temperature Interrupt Mask Register (0x43)
BIT#
Name
Type
Description
0
MASKLTV
R/W
Mask Local Temperature Violation bit.
0: Allow ATV bit to affect INT output.
1: Prohibit ATV bit from affecting the INT output.
1
MASKRTV2
R/W
Mask Remote Diode 2 Temperature Violation.
0: Allow RTV2 bit to assert INT output.
1: Prevent RTV2 bit from asserting the INT output.
2
MASKFAULT_D2
R/W
Mask Remote Diode 2 Fault bit.
0: Allow FAULT_D2 bit to assert the INT output.
1: Prohibit FAULT_D2 bit from asserting the INT output.
3
MASKITHERM
R/W
Mask Internal THERM.
0: Allow ITHERM to affect INT output.
1: Block ITHERM from affecting the INT output.
4
Reserved
5
MASKRTV1
R/W
Mask Remote Diode 1 Temperature Violation bit.
0: Allow RTV1 bit to assert INT output.
1: Prevent RTV1 bit from asserting the INT output.
6
MSKTHERM
R/W
Mask THERM bit.
0: Allow THERM bit to affect INT output.
1: Block THERM bit from affecting the INT output.
7
MASKFAULT_D1
R/W
Mask Remote Diode 1 Fault bit.
0: Allow FAULT_D1 bit to assert the INT output.
1: Prohibit FAULT_D1 bit from asserting the INT output.
Temperature Status Register (0x41) (continued)
BIT#
Name
Type
Description