KMA210
All information provided in this document is subject to legal disclaimers.
NXP B.V. 2011. All rights reserved.
Product data sheet
Rev. 1 — 30 June 2011
29 of 36
NXP Semiconductors
KMA210
Programmable angle sensor
15. ElectroStatic Discharge (ESD)
15.1 Human body model (AEC-Q100-002)
The KMA210 must not be damaged at 8 kV, according to the human body model at
100 pF and 1.5 k
. This protection is ensured at all external pins (OUT/DATA, V
DD
and
GND).
Classification level: H3B.
Furthermore, all interconnects (pins between package head and package body) must not
be damaged at 2 kV.
Classification level: H2.
15.2 Human metal model (ANSI/ESD SP5.6-2009)
The KMA210 must not be damaged at 8 kV, according to the human metal model at
150 pF and 330
inside the ESD gun. This test utilizes waveforms of the IEC 61000-4-2
standard on component level. The contact discharge will be applied in an unsupplied state
at pins OUT/DATA and V
DD
referred to GND which is connected directly to the ground
plane.
Test setup: A.
Test level: 5.
15.3 Machine model (AEC-Q100-003)
The KMA210 must not be damaged at 400 V, according to the machine model.
This protection is ensured at all external pins (OUT/DATA, V
DD
and GND).
Classification level: M4.
Furthermore, all interconnects (pins between package head and package body) must not
be damaged at 200 V.
Classification level: M3.
All pins have latch-up protection.
15.4 Charged-device model (AEC-Q100-011)
The KMA210 must not be damaged at 750 V, according to the charged-device model.
This protection is ensured at all external pins (OUT/DATA, V
DD
and GND).
Classification level: C4.
Furthermore, all interconnects (pins between package head and package body) must not
be damaged at 500 V.
Classification level: C3B.