M50LPW041
Communication Frame, LFRAME, is Low, V
IL
, as
Clock rises and the correct Start cycle is on LAD0-
LAD3. On the following Clock cycles the Host will
send the Cycle Type + Dir, Address, other control
bits, Data0-Data3 and Data4-Data7 on LAD0-
LAD3. The memory outputs Sync data until the
wait-states have elapsed.
Refer to Table 8, LPC Bus Write Field Definitions,
and Figure 6, LPC Bus Write Waveforms, for a
description of the Field definitions for each clock
cycle of the transfer. See Table 23, LPC Interface
AC Signal Timing Characteristics and Figure 10,
LPC Interface AC Signal Timing Waveforms, for
details on the timings of the signals.
Bus Abort.
The Bus Abort operation can be used
to immediately abort the current bus operation. A
Bus Abort occurs when LFRAME is driven Low,
V
IL
, during the bus operation; the memory will tri-
state the Input/Output Communication pins,
LAD0-LAD3.
Note that, during a Bus Write operation, the
Command
Interface
command as soon as the data is fully received; a
Bus Abort during the final TAR cycles is not
guaranteed to abort the command; the bus,
however, will be released immediately.
Standby.
When LFRAME is High, V
IH
, the
memory is put into Standby mode where LAD0-
LAD3 are put into a high-impedance state and the
Supply Current is reduced to the Standby level,
I
CC1
.
Reset.
During Reset mode all internal circuits are
switched off, the memory is deselected and the
outputs are put in high-impedance. The memory is
in Reset mode when Interface Reset, RP, or CPU
Reset, INIT, is Low, V
IL
. RP or INIT must be held
starts
executing
the
Low, V
IL
, for t
PLPH
. The memory resets to Read
mode upon return from Reset mode and the Lock
Registers return to their default states regardless
of their state before Reset, see Table 16. If RP or
INIT goes Low, V
IL
, during a Program or Erase
operation, the operation is aborted and the
memory cells affected no longer contain valid
data; the memory can take up to t
PLRH
to abort a
Program or Erase operation.
Block Protection.
Block
forced using the signals Top Block Lock, TBL, and
Write Protect, WP, regardless of the state of the
Lock Registers.
Address/Address Multiplexed (A/A Mux) Bus
Operations
The Address/Address Multiplexed (A/A Mux)
Interface has a more traditional style interface.
The signals consist of a multiplexed address
signals (A0-A10), data signals, (DQ0-DQ7) and
three control signals (RC, G, W). An additional
signal, RP, can be used to reset the memory.
The Address/Address Multiplexed (A/A Mux)
Interface
is
included
Programming equipment
programming. Only a subset of the features
available to the Low Pin Count (LPC) Interface are
available; these include all the Commands but
exclude the Security features and other registers.
The following operations can be performed using
the appropriate bus cycles: Bus Read, Bus Write,
Output Disable and Reset.
When the Address/Address Multiplexed (A/A Mux)
Interface is
selected all the blocks
unprotected. It is not possible to protect any blocks
through this interface.
Protection
can
be
for
use
faster factory
by
Flash
for
are
Table 5. Absolute Maximum Ratings
(1)
Note: 1. Except for the rating "Operating Temperature Range", stresses above those listed in the Table "Absolute Maximum Ratings" may
cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions
above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating condi-
tions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant qual-
ity documents.
2. Minimum Voltage may undershoot to -2V and for less than 20ns during transitions. Maximum Voltage may overshoot to V
CC
+2V
and for less than 20ns during transitions.
Symbol
Parameter
Value
Unit
T
A
Ambient Operating Temperature (Temperature Range Option 1)
0 to 70
°C
T
BIAS
Temperature Under Bias
–50 to 125
°C
T
STG
Storage Temperature
–65 to 150
°C
V
IO (2)
Input or Output Voltage
–0.6 to V
CC
+ 0.6
V
V
CC
Supply Voltage
–0.6 to 4
V
V
PP
Program Voltage
–0.6 to 13
V