3–184
Motorola Sensor Device Data
For More Information On This Product,
Go to: www.freescale.com
MAXIMUM RATINGS(1)
Parametrics
Symbol
Value
Units
Maximum Pressure (P1
P2)
Pmax
Tstg
TA
Io+
Io–
400
kPa
Storage Temperature
–40
°
to +125
°
°
C
Operating Temperature
Output Source Current @ Full Scale Output(2)
Output Sink Current @ Minimum Pressure Offset(2)
–40
°
to +125
°
°
C
0.5
mAdc
–0.5
mAdc
NOTES:
1. Exposure beyond the specified limits may cause permanent damage or degradation to the device.
2. Maximum Output Current is controlled by effective impedance from Vout to Gnd or Vout to VS in the application circuit.
OPERATING CHARACTERISTICS
(VS = 5.0 Vdc, TA = 25
°
C unless otherwise noted, P1
Characteristic
P2.)
Symbol
Min
Typ
Max
Unit
Pressure Range
Supply Voltage(1)
POP
VS
Io
VFSO
–115
—
0
kPa
4.75
5.0
5.25
Vdc
Supply Current
Full Scale Output(2)
@ VS = 5.0 Volts
Full Scale Span(3)
@ VS = 5.0 Volts
Accuracy(4)
—
6.0
10
mAdc
(0 to 85
°
C)
(Pdiff = 0 kPa)
4.534
4.6
4.665
Vdc
(0 to 85
°
C)
VFSS
—
4.4
—
Vdc
(0 to 85
°
C)
—
—
—
±
1.5
%VFSS
mV/kPa
Sensitivity
Response Time(5)
Warm–Up Time(6)
Offset Stability(7)
V/P
—
38.26
—
tR
—
—
1.0
—
ms
—
20
—
ms
—
—
±
0.5
—
%VFSS
NOTES:
1. Device is ratiometric within this specified excitation range.
2. Full Scale Output (VFSO) is defined as the output voltage at the maximum or full rated pressure.
3. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
4. Accuracy is the deviation in actual output from nominal output over the entire pressure range and temperature range as a percent of span
at 25
°
C due to all sources of error including the following:
Linearity:
Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
cycled to and from the minimum or maximum operating temperature points, with zero differential
pressure applied.
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from
minimum or maximum rated pressure at 25
°
C.
TcSpan:
Output deviation over the temperature range of 0
°
to 85
°
C, relative to 25
°
C.
TcOffset:
Output deviation with minimum pressure applied, over the temperature range of 0
°
to 85
°
C, relative
to 25
°
C.
5. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
6. Warm–up Time is defined as the time required for the product to meet the specified output voltage after the pressure has been stabilized.
7. Offset Stability is the product’s output deviation when subjected to 1000 cycles of Pulsed Pressure, Temperature Cycling with Bias Test.
F
Freescale Semiconductor, Inc.