3–127
Motorola Sensor Device Data
For More Information On This Product,
Go to: www.freescale.com
MAXIMUM RATINGS(1)
Parametrics
Symbol
Value
Unit
Maximum Pressure(2) (P1 > P2)
P1max
Tstg
TA
4000
kPa
Storage Temperature
–40
°
to +125
°
C
Operating Temperature
–40
°
to +125
°
C
NOTES:
1. Extended exposure at the specified limits may cause permanent damage or degradation to the device.
2. This sensor is designed for applications where P1 is always greater than, or equal to P2. P2 maximum is 500 kPa.
OPERATING CHARACTERISTICS
(VS = 5.0 Vdc, TA = 25
°
C unless otherwise noted, P1 > P2. Decoupling circuit shown in Figure 4
required to meet electrical specifications.)
Characteristic
Symbol
Min
Typ
Max
Unit
Pressure Range(1)
Supply Voltage(2)
POP
VS
Io
Voff
VFSO
VFSS
V/P
0
—
1000
kPa
4.75
5.0
5.25
Vdc
Supply Current
Zero Pressure Offset(3)
Full Scale Output(4)(0 to 85
°
C)
Full Scale Span(5) (0 to 85
°
C)
—
7.0
10
mAdc
(0 to 85
°
C)
0.088
0.2
0.313
Vdc
4.587
4.7
4.813
Vdc
—
4.5
—
Vdc
Sensitivity
Accuracy(6)
Response Time(7)
—
4.5
—
mV/kPa
(0 to 85
°
C)
—
—
—
±
2.5
%VFSS
ms
tR
IO+
—
—
1.0
—
Output Source Current at Full Scale Output
Warm–Up Time(8)
—
0.1
—
mA
—
20
—
ms
NOTES:
1. 1.0 kPa (kiloPascal) equals 0.145 psi.
2. Device is ratiometric within this specified excitation range.
3. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
4. Full Scale Output (VFSO) is defined as the output voltage at the maximum or full rated pressure.
5. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at full rated pressure and the output voltage at the
minimum rated pressure.
6. Accuracy (error budget) consists of the following:
Linearity:
Output deviation from a straight line relationship with pressure over the specified pressure range.
Temperature Hysteresis: Output deviation at any temperature within the operating temperature range, after the temperature is
cycled to and from the minimum or maximum operating temperature points, with zero differential pressure
applied.
Pressure Hysteresis:
Output deviation at any pressure within the specified range, when this pressure is cycled to and from the
minimum or maximum rated pressure, at 25
°
C.
TcSpan:
Output deviation over the temperature range of 0
°
to 85
°
C, relative to 25
°
C.
TcOffset:
Output deviation with minimum rated pressure applied, over the temperature range of 0
°
to 85
°
C, relative
to 25
°
C.
Variation from Nominal:
The variation from nominal values, for Offset or Full Scale Span, as a percent of VFSS, at 25
°
C.
7. Response Time is defined as the time for the incremental change in the output to go from 10% to 90% of its final value when subjected to
a specified step change in pressure.
8. Warm–up Time is defined as the time required for the device to meet the specified output voltage after the pressure has been stabilized.
MECHANICAL CHARACTERISTICS
Characteristics
Typ
Unit
Weight, Basic Element (Case 867)
4.0
grams
F