參數(shù)資料
型號: V54C365804VCT8L
廠商: MOSEL-VITELIC
元件分類: DRAM
英文描述: 8M X 8 SYNCHRONOUS DRAM, 7 ns, PDSO54
封裝: 0.400 INCH, PLASTIC, TSOP2-54
文件頁數(shù): 54/54頁
文件大小: 453K
代理商: V54C365804VCT8L
MOSEL VITELIC
V54C365804VC
9
V54C365804VC Rev. 0.6 September 1999
operation. If CA10 is high when a Read Command
is issued, the Read with Auto-Precharge function
is initiated. The SDRAM automatically enters the
precharge operation one clock before the last data
out for CAS latencies 2, two clocks for CAS laten-
cies 3 and three clocks for CAS latencies 4. If
CAS10 is high when a Write Command is issued,
the Write with Auto-Precharge function is initiat-
ed. The SDRAM automatically enters the precharge
operation a time delay equal to tWR (Write recovery
time) after the last data in.
Precharge Command
There is also a separate precharge command
available. When RAS and WE are low and CAS is
high at a clock timing, it triggers the precharge op-
eration. Three address bits, BA0, BA1 and A10 are
used to define banks as shown in the following list.
The precharge command can be imposed one clock
before the last data out for CAS latency = 2, two
clocks before the last data out for CAS latency = 3
and three clocks before the last data out for CAS la-
tency= 4. Writes require a time delay twr from the
last data out to apply the precharge command.
Bank Selection by Address Bits:
Burst Termination
Once a burst read or write operation has been ini-
tiated, there are several methods in which to termi-
nate the burst operation prematurely. These
methods include using another Read or Write Com-
mand to interrupt an existing burst operation, use a
Precharge Command to interrupt a burst cycle and
close the active bank, or using the Burst Stop Com-
mand to terminate the existing burst operation but
leave the bank open for future Read or Write Com-
mands to the same page of the active bank. When
interrupting a burst with another Read or Write
Command care must be taken to avoid I/O conten-
tion. The Burst Stop Command, however, has the
fewest restrictions making it the easiest method to
use when terminating a burst operation before it has
been completed. If a Burst Stop command is issued
during a burst write operation, then any residual
data from the burst write cycle will be ignored. Data
that is presented on the I/O pins before the Burst
Stop Command is registered will be written to the
memory.
A10
BA0
BA1
0
Bank 0
0
1
Bank 1
0
1
0
Bank 2
0
1
Bank 3
1
X
all Banks
相關(guān)PDF資料
PDF描述
V55C2256164VGLK-10H SYNCHRONOUS DRAM, PBGA54
V585ME07 VCO, 1100 MHz - 2100 MHz
V585ME14 VCO, 1470 MHz - 1875 MHz
V58C2128404SBLT6I 32M X 4 DDR DRAM, 0.7 ns, PDSO66
V58C365164S5 4M X 16 DDR DRAM, 0.1 ns, PDSO66
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
V54C365804VD 制造商:MOSEL 制造商全稱:MOSEL 功能描述:HIGH PERFORMANCE 143/133/125 MHz 3.3 VOLT 8M X 8 SYNCHRONOUS DRAM 4 BANKS X 2Mbit X 8
V5-5/RK 4-0.3/0.3/0.3 制造商:TURCK Inc 功能描述:Cordset, Splitter, M12 Female Straight x 3, 4 Wire, 5m, PVC, Yellow, U0986-00
V5-5/RK 4-1/1/1 制造商:TURCK Inc 功能描述:Cordset, Splitter, M12 Female Straight x 3, 4 Wire, 5m, PVC, Yellow, U-16415
V5509 制造商:Assmann Electronics Inc 功能描述:Old Part V5509^ASSMANN
V550-A20 制造商:Omron Electronic Components LLC 功能描述:Bar Code Reader, Bcr With Standard Optics