Platform Flash In-System Programmable Configuration PROMs
DS123 (v2.18) May 19, 2010
Product Specification
19
R
TCYCO
Clock period(7) (serial mode) when VCCO = 3.3V or 2.5V
30
–
ns
Clock period(7) (serial mode) when VCCO = 1.8V
30
–
ns
Clock period(7) (parallel mode) when VCCO = 3.3V or 2.5V
35
–
ns
Clock period(7) (parallel mode) when VCCO = 1.8V
35
–
ns
TLC
CLK Low time(3) when VCCO = 3.3V or 2.5V
12
–
ns
CLK Low time(3) when VCCO = 1.8V
12
–
ns
THC
CLK High time(3) when VCCO = 3.3V or 2.5V
12
–
ns
CLK High time(3) when VCCO = 1.8V
12
–
ns
THCE
CE hold time (guarantees counters are reset)(5) when VCCO = 3.3V or 2.5V
2000
–
ns
CE hold time (guarantees counters are reset)(5) when VCCO = 1.8V
2000
–
ns
THOE
OE/RESET hold time (guarantees counters are reset)(6) when VCCO = 3.3V or 2.5V
2000
–
ns
OE/RESET hold time (guarantees counters are reset)(6) when VCCO = 1.8V
2000
–
ns
TSB
BUSY setup time to CLKOUT when VCCO = 3.3V or 2.5V
12
–
ns
BUSY setup time to CLKOUT when VCCO = 1.8V
12
–
ns
THB
BUSY hold time to CLKOUT when VCCO = 3.3V or 2.5V
8
–
ns
BUSY hold time to CLKOUT when VCCO = 1.8V
8
–
ns
TCLKO
CLK input to CLKOUT output delay when VCCO = 3.3V or 2.5V
–
35
ns
CLK input to CLKOUT output delay when VCCO = 1.8V
–
35
ns
CLK input to CLKOUT output delay when VCCO = 3.3V or 2.5V
with decompression(12)
–35
ns
CLK input to CLKOUT output delay when VCCO = 1.8V
with decompression(12)
–35
ns
TCECC
CE to CLKOUT delay(8) when VCCO = 3.3V or 2.5V
0
2 CLK
cycles
–
CE to CLKOUT delay(8) when VCCO = 1.8V
0
2 CLK
cycles
–
TOECC
OE/RESET to CLKOUT delay(8) when VCCO = 3.3V or 2.5V
02 CLK
cycles
–
OE/RESET to CLKOUT delay(8) when VCCO = 1.8V
02 CLK
cycles
–
TCFCC
CF to CLKOUT delay(8) when VCCO = 3.3V or 2.5V
0
–
CF to CLKOUT delay(8) when VCCO = 1.8V
0
–
TCCDD
CLKOUT to data delay when VCCO = 3.3V or 2.5V(9)
–30
ns
CLKOUT to data delay when VCCO = 1.8V(9)
–30
ns
TDDC
Data setup time to CLKOUT when VCCO = 3.3V or 2.5V with decompression(9)(12)
5ns
Data setup time to CLKOUT when VCCO = 1.8V with decompression(9)(12)
5ns
TCOH
Data hold from CLKOUT when VCCO = 3.3V or 2.5V
3
–
ns
Data hold from CLKOUT when VCCO = 1.8V
3
–
ns
Data hold from CLKOUT when VCCO = 3.3V or 2.5V with decompression(12)
3–
ns
Data hold from CLKOUT when VCCO = 1.8V with decompression(12)
3–
ns
TSXT
EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 3.3V or 2.5V
300
–
ns
EN_EXT_SEL setup time to CF, CE, or OE/RESET when VCCO = 1.8V
300
–
ns
Symbol
Description
XCF08P, XCF16P,
XCF32P
Units
Min
Max