AD5520
Rev. B | Page 5 of 24
Parameter
Min
Max
Unit
Test Conditions/Comments
POWER REQUIREMENTS
AVCC
14.25
15
15.75
V
for specific performanc
e6AVEE
14.25
15
+15.75
V
Power Supply Rejection Ratio,
PSRR1FOH
25
dB
100 kHz
16
dB
500 kHz
15
dB
1 MHz
MEASOUT
55
dB
100 kHz
10
dB
500 kHz
DC PSR
90
dB
DVDD
5
V
IAVCC
12
mA
IAVEE
12
mA
IDVDD
0.5
mA
Digital inputs at supply rails
1 Typical values are at 25°C and nominal supply, unless otherwise noted.
2 Full-scale = 11 V.
3 Full-scale range = 22 V.
4 Guaranteed by design and characterization, but not subject to production test.
5 Force control amplifier dominates slew rate and settling time.
6 Operational with ±12 V supplies, force/measure range is reduced to ±8.5 V.