第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)當(dāng)前第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)
Am79C972
55
mediately request the bus in order to access the next
TDTE location in the ring.
If the OWN bit is set and the buffer length is 0, the OWN
bit will be cleared. In the C-LANCE device, the buffer
length of 0 is interpreted as a 4096-byte buffer. A zero
length buffer is acceptable as long as it is not the last
buffer in a chain (STP = 0 and ENP = 1).
If the OWN bit and STP are set, then microcode control
proceeds to a routine that will enable transmit data
transfers to the FIFO. The Am79C972 controller will
look ahead to the next transmit descriptor after it has
performed at least one transmit data transfer from the
first buffer.
If the Am79C972 controller does not own the next
TDTE (i.e., the second TDTE for this frame), it will com-
plete transmission of the current buffer and update the
status of the current (first) TDTE with the BUFF and
UFLO bits being set. If DXSUFLO (CSR3, bit 6) is
cleared to 0, the underflow error will cause the transmit-
ter to be disabled (CSR0, TXON = 0). The Am79C972
controller will have to be re-initialized to restore the
transmit function. Setting DXSUFLO to 1 enables the
Am79C972 controller to gracefully recover from an un-
derflow error. The device will scan the transmit descrip-
tor ring until it finds either the start of a new frame or a
TDTE it does not own. To avoid an underflow situation
in a chained buffer transmission, the system should al-
ways set the transmit chain descriptor own bits in re-
verse order.
If the Am79C972 controller does own the second TDTE
in a chain, it will gradually empty the contents of the first
buffer (as the bytes are needed by the transmit opera-
tion), perform a single-cycle DMA transfer to update the
status of the first descriptor (clear the OWN bit in
TMD1), and then it may perform one data DMA access
on the second buffer in the chain before executing an-
other lookahead operation. (i.e., a lookahead to the
third descriptor.)
It is imperative that the host system never reads the
TDTE OWN bits out of order. The Am79C972 controller
normally clears OWN bits in strict FIFO order. However,
the Am79C972 controller can queue up to two frames
in the transmit FIFO. When the second frame uses
buffer chaining, the Am79C972 controller might return
ownership out of normal FIFO order. The OWN bit for
last (and maybe only) buffer of the first frame is not
cleared until transmission is completed. During the
transmission the Am79C972 controller will read in buff-
ers for the next frame and clear their OWN bits for all
but the last one. The first and all intermediate buffers of
the second frame can have their OWN bits cleared be-
fore the Am79C972 controller returns ownership for the
last buffer of the first frame.
If an error occurs in the transmission before all of the
bytes of the current buffer have been transferred, trans-
mit status of the current buffer will be immediately up-
dated. If the buffer does not contain the end of packet,
the Am79C972 controller will skip over the rest of the
frame which experienced the error. This is done by re-
turning to the polling microcode where the Am79C972
controller will clear the OWN bit for all descriptors with
OWN = 1 and STP = 0 and continue in like manner until
a descriptor with OWN = 0 (no more transmit frames in
the ring) or OWN = 1 and STP = 1 (the first buffer of a
new frame) is reached.
At the end of any transmit operation, whether success-
ful or with errors, immediately following the completion
of the descriptor updates, the Am79C972 controller will
always perform another polling operation. As described
earlier, this polling operation will begin with a check of
the current RDTE, unless the Am79C972 controller al-
ready owns that descriptor. Then the Am79C972 con-
troller will poll the next TDTE. If the transmit descriptor
OWN bit has a 0 value, the Am79C972 controller will
resume incrementing the poll time counter. If the trans-
mit descriptor OWN bit has a value of 1, the Am79C972
controller will begin filling the FIFO with transmit data
and initiate a transmission. This end-of-operation poll
coupled with the TDTE lookahead operation allows the
Am79C972 controller to avoid inserting poll time counts
between successive transmit frames.
By default, whenever the Am79C972 controller com-
pletes a transmit frame (either with or without error) and
writes the status information to the current descriptor,
then the TINT bit of CSR0 is set to indicate the comple-
tion of a transmission. This causes an interrupt signal if
the IENA bit of CSR0 has been set and the TINTM bit
of CSR3 is cleared. The Am79C972 controller provides
two modes to reduce the number of transmit interrupts.
The interrupt of a successfully transmitted frame can
be suppressed by setting TINTOKD (CSR5, bit 15) to
1. Another mode, which is enabled by setting LTINTEN
(CSR5, bit 14) to 1, allows suppression of interrupts for
successful transmissions for all but the last frame in a
sequence.
Receive Descriptor Table Entry
If the Am79C972 controller does not own both the cur-
rent and the next Receive Descriptor Table Entry
(RDTE), then the Am79C972 controller will continue to
poll according to the polling sequence described
above. If the receive descriptor ring length is one, then
there is no next descriptor to be polled.
If a poll operation has revealed that the current and the
next RDTE belong to the Am79C972 controller, then
additional poll accesses are not necessary. Future poll
operations will not include RDTE accesses as long as
the Am79C972 controller retains ownership of the cur-
rent and the next RDTE.
When receive activity is present on the channel, the
Am79C972 controller waits for the complete address of
相關(guān)PDF資料
PDF描述
AM79C974 PCnetTM-SCSI Combination Ethernet and SCSI Controller for PCI Systems
AM79C974KCW PCnetTM-SCSI Combination Ethernet and SCSI Controller for PCI Systems
AM79C975 PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973 PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973KCW PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AM79C973 制造商:AMD 制造商全稱:Advanced Micro Devices 功能描述:PCnet⑩-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973/75 制造商:未知廠家 制造商全稱:未知廠家 功能描述:Board Layout Considerations for the Am79C973/75 Network Interface? - (PDF)
AM79C973/AM79C975 制造商:AMD 制造商全稱:Advanced Micro Devices 功能描述:Am79C973/Am79C975 - PCnet-FAST III Single-Chip 10/100 Mbps PCI Ethernet Controller with Integrated PHY
AM79C973AVC\\W 制造商:Advanced Micro Devices 功能描述:
AM79C973AVC\W 制造商:Advanced Micro Devices 功能描述: