參數(shù)資料
型號(hào): AOP-PXB4340
英文描述: ATM OAM Processor
中文描述: 自動(dòng)柜員機(jī)的OAM處理器
文件頁(yè)數(shù): 27/185頁(yè)
文件大小: 2552K
代理商: AOP-PXB4340
第1頁(yè)第2頁(yè)第3頁(yè)第4頁(yè)第5頁(yè)第6頁(yè)第7頁(yè)第8頁(yè)第9頁(yè)第10頁(yè)第11頁(yè)第12頁(yè)第13頁(yè)第14頁(yè)第15頁(yè)第16頁(yè)第17頁(yè)第18頁(yè)第19頁(yè)第20頁(yè)第21頁(yè)第22頁(yè)第23頁(yè)第24頁(yè)第25頁(yè)第26頁(yè)當(dāng)前第27頁(yè)第28頁(yè)第29頁(yè)第30頁(yè)第31頁(yè)第32頁(yè)第33頁(yè)第34頁(yè)第35頁(yè)第36頁(yè)第37頁(yè)第38頁(yè)第39頁(yè)第40頁(yè)第41頁(yè)第42頁(yè)第43頁(yè)第44頁(yè)第45頁(yè)第46頁(yè)第47頁(yè)第48頁(yè)第49頁(yè)第50頁(yè)第51頁(yè)第52頁(yè)第53頁(yè)第54頁(yè)第55頁(yè)第56頁(yè)第57頁(yè)第58頁(yè)第59頁(yè)第60頁(yè)第61頁(yè)第62頁(yè)第63頁(yè)第64頁(yè)第65頁(yè)第66頁(yè)第67頁(yè)第68頁(yè)第69頁(yè)第70頁(yè)第71頁(yè)第72頁(yè)第73頁(yè)第74頁(yè)第75頁(yè)第76頁(yè)第77頁(yè)第78頁(yè)第79頁(yè)第80頁(yè)第81頁(yè)第82頁(yè)第83頁(yè)第84頁(yè)第85頁(yè)第86頁(yè)第87頁(yè)第88頁(yè)第89頁(yè)第90頁(yè)第91頁(yè)第92頁(yè)第93頁(yè)第94頁(yè)第95頁(yè)第96頁(yè)第97頁(yè)第98頁(yè)第99頁(yè)第100頁(yè)第101頁(yè)第102頁(yè)第103頁(yè)第104頁(yè)第105頁(yè)第106頁(yè)第107頁(yè)第108頁(yè)第109頁(yè)第110頁(yè)第111頁(yè)第112頁(yè)第113頁(yè)第114頁(yè)第115頁(yè)第116頁(yè)第117頁(yè)第118頁(yè)第119頁(yè)第120頁(yè)第121頁(yè)第122頁(yè)第123頁(yè)第124頁(yè)第125頁(yè)第126頁(yè)第127頁(yè)第128頁(yè)第129頁(yè)第130頁(yè)第131頁(yè)第132頁(yè)第133頁(yè)第134頁(yè)第135頁(yè)第136頁(yè)第137頁(yè)第138頁(yè)第139頁(yè)第140頁(yè)第141頁(yè)第142頁(yè)第143頁(yè)第144頁(yè)第145頁(yè)第146頁(yè)第147頁(yè)第148頁(yè)第149頁(yè)第150頁(yè)第151頁(yè)第152頁(yè)第153頁(yè)第154頁(yè)第155頁(yè)第156頁(yè)第157頁(yè)第158頁(yè)第159頁(yè)第160頁(yè)第161頁(yè)第162頁(yè)第163頁(yè)第164頁(yè)第165頁(yè)第166頁(yè)第167頁(yè)第168頁(yè)第169頁(yè)第170頁(yè)第171頁(yè)第172頁(yè)第173頁(yè)第174頁(yè)第175頁(yè)第176頁(yè)第177頁(yè)第178頁(yè)第179頁(yè)第180頁(yè)第181頁(yè)第182頁(yè)第183頁(yè)第184頁(yè)第185頁(yè)
3;%(
Data Sheet
2-27
04.2000
)XQFWLRQDO'HVFULSWLRQ
2$0)XQFWLRQV2YHUYLHZ
There are two groups of applications for OAM functions: alarms and measurements. Alarm
functions inform users and network operators about network failures. These include the OAM
functions
Alarm Indication Signal (AIS)
Remote Defect Indication (RDI)
Continuity Check (CC).
AIS and RDI are used to convey transmission line failure information to subscriber and network
operator; CC detects ATM layer failures.
As failure events are unpredictable the alarm supervising HW is always running. When a failure
occurs the notification process starts automatically.
Measurements are initiated for diagnosis purposes by the network operator. Therefore these
functions do not need to be active permanently for all connections. The respective OAM
functions are:
Loopback LB
Performance Monitoring PM
LB checks the connectivity of a connection by sending a single cell which is looped back at
predefined points. LB is used e.g. immediately after connection set-up or periodically to check
all permanent connections of a network using end-to-end or segment LB. A network operator
could also use intra-domain LB to localize a failed link. Another option for loopback are
subscriber initiated loops either end-to-end to the partner or access line LB to the first node in
the network.
PM is a more precise tool than LB. It checks not only the connectivity, but the real performance
of a connection in terms of bit failures and cell losses. As it requires complex HW support and
SW performance PM will not be activated permanently for all connections. E.g. VPCs or
permanent VCCs could be monitored if a subscriber pays for this service. Also a network
operator would use PM to check the quality of a connection if a subscriber complains about it.
$ODUP2$0)XQFWLRQV$,65',&&
There are two types of failures detected by the alarm functions: transmission line failures and
ATM layer failures. Transmission line failures are e.g. line brakes, failures of lasers or failures of
reception diodes. Typical ATM layer failures are the misrouting of cells in the switching fabric or
a falsified entry in a routing table. In this case all cells of a connection are forwarded to a wrong
destination.
7UDQVPLVVLRQ/LQH)DLOXUHV$,65',
Transmission line failures are recognized by the receiving PHY and conveyed to the PXB 4340
AOP by the on-board control processor. It is sufficient to set one single bit for the respective PHY
to initiate the periodic insertion of AIS cells for all affected connections. In the external RAM entry
a bit CARIEN exists for F5-AIS and a bit PARIEN for F4-AIS ( for CARIEN see
VHFWLRQ
page 100, for upstream and
VHFWLRQ
VHFWLRQ
page 107, for upstream and
VHFWLRQ
these bits are set to ’1’, the insertion of AIS cells is enabled. Note, that no F4 OAM/User-Flow is
supported if the LCI-Mode "10" in register UTCONF1 is selected (see
VHFWLRQ
Further the bit DISF4 and DISF5 in the external RAM entries have to be set to ’0’ to enable the
page 112, for downstream; for PARIEN see
page 118, for downstream). When
page 88).
相關(guān)PDF資料
PDF描述
AOP3510F1 Voltage-Feedback Operational Amplifier
AOP3510J3 Voltage-Feedback Operational Amplifier
AOP8 ISA BUS KARTE 8KANAL D/A WANDLER 12BIT
AP-30711P2-301 Converter
AP-30711P2-301V Converter
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AOQW-100 制造商:IDEC CORPORATION 功能描述:TW SQ FLUSH OPER PB
AOQW101-B 制造商:IDEC CORPORATION 功能描述:TW SQ FLUSH PB
AOQW101FN-W/O 制造商:IDEC CORPORATION 功能描述:COLOR BUTTON
AOQW101-G 制造商:IDEC CORPORATION 功能描述:TW SQ FLUSH PB
AOQW101-R 制造商:IDEC CORPORATION 功能描述:TW SQ FLUSH PB