DS1314
6 of 12
VBAT Trip Point
VBTP
2.5
2.6
2.7
V
2
VCC/VBAT Switch Point
(TOL=GND)
VSW
2.6
2.7
2.8
V
2
VCC/VBAT Switch Point
(TOL= VCCO)
VSW
2.4
2.5
2.6
V
2
Output Current @ 2.2V
IOH
-1
mA
8, 11
Output Current @ 0.4V
IOL
4
mA
8, 11
Input Leakage
IIL
-1.0
+1.0
A
Output Leakage
ILO
-1.0
+1.0
A
Battery Monitoring Test Load
RINT
0.8
1.2
1.5
MΩ
DC ELECTRICAL CHARACTERISTICS (-40°C to +85°C; VCCI < VBAT; VCCI < VSW)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Battery Current
IBAT
100
nA
3
Battery-Backup Current
ICCO2
500
A
7
Supply Voltage
VCCO
VBAT-0.2
V
2
CEO
Output
VOHL
VBAT-0.2
V
2, 9
CAPACITANCE
(TA = +25°C)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
Input Capacitance ( CEI , TOL)
CIN
7
pF
Output Capacitance
( CEO , BW , RST )
COUT
7
pF
AC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; VCCI ≥ VCCTP)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
CEI
to CEO Propagation Delay
tPD
12
20
ns
CE
Pulse Width
tCE
1.5
s
12
VCC Valid to End of
Write Protection
tREC
12
125
ms
10
VCC Valid to CEI Inactive
tPU
2
ms
VCC Valid to RST Inactive
tRPU
150
200
350
ms
11
VCC Valid to BW Valid
tBPU
1
s
11
AC ELECTRICAL CHARACTERISTICS
(-40°C to +85°C; VCCI < VCCTP)
PARAMETER
SYMBOL
MIN
TYP
MAX
UNITS
NOTES
VCC Slew Rate
tF
150
s
VCC Fail Detect to RST Active
tRPD
5
15
s
11
VCC Slew Rate
tR
150
s