2-72
Intel
Integrated RAID Controller GSU31
User
’
s Manual
Rev 1.0
Advanced Installation Steps
2.5.10.4
Installing Novell NetWare on an IDE Disk or Non-RAID SCSI Disk
This procedure installs Novell NetWare on an IDE disk or non-RAID SCSI disk. It is typically used
on a system where the operating system is on a disk not controlled by GSU31.
NetWare 4.2
Have all hardware and software on hand. See system requirements in
Section 2.5.10.2
.
GSU31 Hardware Installation
See
Section 1.4, Install the Adapter Card
for detailed hardware installation procedures.
Intel Integrated RAID Software Installation
1. Insert a bootable MS-DOS floppy and reboot. Once you reboot, you will have to run FDISK to
create a DOS partition of at least 50MB on the IDE disk or non-RAID SCSI disk (make sure it
is flagged as the
“
Active
”
partition). Reboot and format the new partition.
2. Copy the desired MS-DOS files to the hard drive, copy the necessary CD-ROM drivers (e.g.
ATAPI_CD.SYS and MSCDEX.EXE) and create a CONFIG.SYS and AUTOEXEC.BAT that
loads those drivers. Insert the following lines in the CONFIG.SYS file:
files=30
buffer=20
3. Reboot the server, insert the NetWare Installation CD-ROM, go to the appropriate drive letter
and run INSTALL.BAT.
4. After booting you will first be asked to Accept the License Agreement. Do so and then select
“
NetWare 4.2
”
, then select
“
Custom installation of NetWare 4.2
”
. Enter the server name and
internal network number. Hit <Enter> to begin the initial file copy.
5. Confirm the locale configuration and select
“
Continue
”
. Modify the NCF files. Make any
desired modifications. Next, the device driver installation screen appears.
6. Choose
“
Select additional or modify selected Disk/LAN drivers
”
.
7. Choose
“
Select an additional driver
”
. Hit <Insert> to install an unlisted driver. Make sure that
the GSU31 NetWare Installation diskette is in the floppy drive and hit <Enter>. Select
“
BKSTROSM.HAM
”
from the list.
8. Continue with the NetWare installation as normal by following the screen prompts.
9. Once the server installation is finished, complete the installation of the GSU31 software suite
by following the steps below.
10. Run "LOAD INSTALL".
11. Select "Product Options", then "Install product not listed". It will tell you that it is going to
scan the A: drive for installation scripts. Ensure the "NetWare Installation" diskette is in the
floppy drive, hit <Enter> to continue.
12. A screen prompt will ask which components you wish to install. A typical installation includes
all components.
BKSTROSM.HAM
SCSIOSM.HAM