參數(shù)資料
型號(hào): ISL6308
廠商: Intersil Corporation
英文描述: Quadruple 2-Input Exclusive-OR Gates 14-SOIC -40 to 85
中文描述: 三相降壓PWM控制器,帶有高電流集成MOSFET驅(qū)動(dòng)器
文件頁(yè)數(shù): 20/27頁(yè)
文件大?。?/td> 765K
代理商: ISL6308
20
FN9208.2
October 19, 2005
dissipating their heat so that the affected channels run hotter
than desired, choose new, smaller values of R
ISEN
for the
affected phases (see the section entitled Channel Current
Balance). Choose R
ISEN,2
in proportion to the desired
decrease in temperature rise in order to cause proportionally
less current to flow in the hotter phase.
In Equation 24, make sure that
T
2
is the desired
temperature rise above the ambient temperature, and
T
1
is
the measured temperature rise above the ambient
temperature. While a single adjustment according to
Equation 24 is usually sufficient, it may occasionally be
necessary to adjust R
ISEN
two or more times to achieve
optimal thermal balance between all channels.
Load Line Regulation Component Selection (DCR
Current Sensing)
For accurate load line regulation, the ISL6308 senses the
total output current by detecting the voltage across the
output inductor DCR of each channel (As described in the
Load Line Regulation
section). As Figure 7 illustrates, an
R-C network is required to accurately sense the inductor
DCR voltage and convert this information into a droop
voltage, which is proportional to the total output current.
Choosing the components for this current sense network is a
two step process. First, R
COMP
and C
COMP
must be
chosen so that the time constant of this R
COMP
-C
COMP
network matches the time constant of the inductor L/DCR.
Then the resistor R
S
must be chosen to set the current
sense network gain, obtaining the desired full load droop
voltage. Follow the steps below to choose the component
values for this R-C network.
1. Choose an arbitrary value for C
COMP
. The recommended
value is 0.01μF.
2. Plug the inductor L and DCR component values, and the
values for C
COMP
chosen in steps 1, into Equation 25 to
calculate the value for R
COMP
.
3. Use the new value for R
COMP
obtained from Equation 25,
as well as the desired full load current, I
FL
, full load droop
voltage, V
DROOP
, and inductor DCR in Equation 26 to
calculate the value for R
S
.
I
DROOP
Due to errors in the inductance or DCR it may be necessary
to adjust the value of R
COMP
to match the time constants
correctly. The effects of time constant mismatch can be seen
in the form of droop overshoot or undershoot during the
initial load transient spike, as shown in Figure 18. Follow the
steps below to ensure the R-C and inductor L/DCR time
constants are matched accurately.
1. Capture a transient event with the oscilloscope set to
about L/DCR/2 (sec/div). For example, with L = 1
μ
H and
DCR = 1m
, set the oscilloscope to 500
μ
s/div.
2. Record
V1 and
V2 as shown in Figure 18.
3. Select a new value, R
COMP,2
, for the time constant
resistor based on the original value, R
COMP,1
, using the
following equation.
V
2
4. Replace R
COMP
with the new value and check to see that
the error is corrected. Repeat the procedure if necessary.
After choosing a new value for R
COMP
, it will most likely be
necessary to adjust the value of R
S
to obtain the desired full
load droop voltage. Use Equation 26 to obtain the new value
for R
S
.
Compensation
The two opposing goals of compensating the voltage
regulator are stability and speed. Depending on whether the
regulator employs the optional load-line regulation as
described in “
Load-Line Regulation
”, there are two distinct
methods for achieving these goals.
Compensating the Load-Line Regulated Converter
The load-line regulated converter behaves in a similar
manner to a peak current mode controller because the two
poles at the output filter L-C resonant frequency split with the
introduction of current information into the control loop. The
final location of these poles is determined by the system
function, the gain of the current signal, and the value of the
compensation components, R
2
and C
1
.
R
ISEN 2
R
ISEN
T
2
T
1
----------
=
(EQ. 24)
R
COMP
COMP
---------------------------------------
=
(EQ. 25)
R
S
------------------------
R
COMP
DCR
=
(EQ. 26)
R
COMP 2
R
COMP 1
1
----------
=
(EQ. 27)
FIGURE 18. TIME CONSTANT MISMATCH BEHAVIOR
V
1
V
OUT
I
TRAN
V
2
I
ISL6308
相關(guān)PDF資料
PDF描述
ISL6308CRZ Three-Phase Buck PWM Controller with High Current Integrated MOSFET Drivers
ISL6308CRZ-T Quadruple 2-Input Exclusive-OR Gates 14-SOIC -40 to 85
ISL6308IRZ-T Three-Phase Buck PWM Controller with High Current Integrated MOSFET Drivers
ISL6315 Two-Phase Multiphase Buck PWM Controller with Integrated MOSFET Drivers(帶集成MOSFET驅(qū)動(dòng)器的雙相降壓PWM控制器)
ISL6316 Quadruple 2-Input Exclusive-OR Gates 14-SOIC -40 to 85
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
ISL6308ACRZ 功能描述:IC CTRLR PWM BUCK 3PHASE 40-QFN RoHS:是 類別:集成電路 (IC) >> PMIC - 穩(wěn)壓器 - 專用型 系列:- 標(biāo)準(zhǔn)包裝:43 系列:- 應(yīng)用:控制器,Intel VR11 輸入電壓:5 V ~ 12 V 輸出數(shù):1 輸出電壓:0.5 V ~ 1.6 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:48-VFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:48-QFN(7x7) 包裝:管件
ISL6308ACRZR5609 制造商:Intersil Corporation 功能描述:PB-FREE DAC-LESS MULTI-PHASE PWM CONTR W/3-DRIVERS, HARD WI - Rail/Tube
ISL6308ACRZ-T 功能描述:IC CTRLR PWM BUCK 3PHASE 40-QFN RoHS:是 類別:集成電路 (IC) >> PMIC - 穩(wěn)壓器 - 專用型 系列:- 標(biāo)準(zhǔn)包裝:43 系列:- 應(yīng)用:控制器,Intel VR11 輸入電壓:5 V ~ 12 V 輸出數(shù):1 輸出電壓:0.5 V ~ 1.6 V 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:48-VFQFN 裸露焊盤 供應(yīng)商設(shè)備封裝:48-QFN(7x7) 包裝:管件
ISL6308ACRZ-TR5609 制造商:Intersil Corporation 功能描述:PB-FREE DAC-LESS MULTI-PHASE PWM CONTR W/3-DRIVERS, HARD WIR - Tape and Reel
ISL6308AEVAL1Z 功能描述:EVALUATION BOARD FOR ISL6308A RoHS:是 類別:編程器,開發(fā)系統(tǒng) >> 評(píng)估板 - DC/DC 與 AC/DC(離線)SMPS 系列:- 產(chǎn)品培訓(xùn)模塊:Obsolescence Mitigation Program 標(biāo)準(zhǔn)包裝:1 系列:True Shutdown™ 主要目的:DC/DC,步升 輸出及類型:1,非隔離 功率 - 輸出:- 輸出電壓:- 電流 - 輸出:1A 輸入電壓:2.5 V ~ 5.5 V 穩(wěn)壓器拓?fù)浣Y(jié)構(gòu):升壓 頻率 - 開關(guān):3MHz 板類型:完全填充 已供物品:板 已用 IC / 零件:MAX8969