Analog Integrated Circuit Device Data
Freescale Semiconductor
20
33970
FUNCTIONAL DEVICE OPERATION
LOGIC COMMANDS AND REGISTERS
table under
POWER OUTPUT AND CLOCK TIMINGS
,
page
7
.
0 = Clock within spec
1 = Clock out of spec
OVUV (OD6) — Undervoltage or Overvoltage Indication. A
logic [1] on this bit indicates the V
PWR
voltage fell to a level
below the V
PWRUV
since the last SPI communication (refer to
the Static Electrical Characteristics table under
POWER
INPUT
, page
5
). An undervoltage event is just flagged, while
an overvoltage event automatically disables the drive
outputs. Because the pointer may not be in the expected
position, the master may want to re-calibrate the pointer with
an RTZ command after the voltage returns to normal level.
For an overvoltage event, both gauges must be re-enabled
as soon as this flag returns to logic [0]. The state machine will
continue to operate properly as long as V
DD
is within the
normal range.
0 = Normal range
1 = Battery voltage fell below V
PWRUV
or exceeded
V
PWROV
MOV1 (OD5) — This bit identifies Gauge 1 Movement
since last SPI communication. A logic [1] on this bit indicates
the Gauge 1 pointer position changed since the last SPI
command. This information allows the master to confirm the
pointer is moving as commanded.
0 = Gauge 1 position has not changed since the last SPI
command
1 = Gauge 1 pointer position has changed since the last
SPI command
MOV0 (OD4) — Gauge 0 Movement Since last SPI
Communication. A logic [1] on this bit indicates the Gauge 0
pointer position has changed since the last SPI command.
This information allows the master to confirm the pointer is
moving as commanded.
0 = Gauge 0 position has not changed since the last SPI
command
1 = Gauge 0 pointer position has changed since the last
SPI command
RTZ1 (OD3) — RTZ1 Is Enabled or Disabled. A logic [1] on
this bit indicates Gauge 1 is in the process of returning to the
zero position as requested with the RTZ command. This bit
will continue to indicate a logic [1] until the SPI message
following a detection of the zero position, or the RTZ feature
is commanded OFF using the RTZ message.
0 = Return to Zero disabled
1 = Return to Zero enabled successfully
RTZ0 (OD2) — RTZ0 Is Enabled or Disabled. A logic [1] on
this bit indicates Gauge 0 is in the process of returning to the
zero position as requested with the RTZ command. This bit
continues to indicate a logic [1] until the SPI message
following a detection of the zero position, or the RTZ feature
is commanded OFF using the RTZ message.
0 = Return to Zero disabled
1 = Return to Zero enabled successfully
OT1 (OD1) — Gauge 1 Junction Overtemperature. A
logic [1] on this bit indicates that the coil drive circuitry
dedicated to drive Gauge 1 has exceeded the maximum
allowable junction temperature since the last SPI
communication and that Gauge 1 has been disabled. It is
recommended that the pointer be re-calibrated using the RTZ
command after re-enabling the gauge using the PECCR
command. This bit remains logic [1] until the gauge is
enabled.
0 = Temperature within range
1 = Gauge 1 maximum allowable junction temperature
condition has been reached
OT0 (OD0) — Gauge 0 Junction Overtemperature. A
logic [1] on this bit indicates that the coil drive circuitry
dedicated to drive Gauge 0 has exceeded the maximum
allowable junction temperature since the last SPI
communication and that Gauge 0 has been disabled. It is
recommended that the pointer be re-calibrated using the RTZ
command after re-enabling the gauge using the PECCR
command. This bit remains logic [1] until the gauge is re-
enabled.
0 = Temperature within range
1 = Gauge 0 maximum allowable junction temperature
condition is reached
RTZ Accumulator Status Information
Most recent valid PECCR command resulting in the RTZ
Accumulator status output:
The bits in
Table 16
are
read-only
bits.
RTZ (OD15) — RTZ Bit Is Enabled or Disabled. A logic [1]
on this bit indicates that the Gauge is in the process of
returning to the zero position as requested with the RTZ
command. This bit will continue to indicate a logic [1] until the
SPI message following a detection of the zero position, or the
RTZ feature is commanded OFF using the RTZ message.
0 = Return to Zero disabled
D11
D10
D9
D8
1
0
x
x
x = Don’t care.
Table 16. RTZ Accumulator Status Output Register
Bits
OD15
OD14
OD13
OD12
OD11
OD10
OD9
OD8
OD7
OD6
OD5
OD4
OD3
OD2
OD1
OD0
Read
RTZ
ACC14 ACC13 ACC12 ACC11
ACC10
ACC9
ACC8
ACC7 ACC6 ACC5 ACC4 ACC3 AC2C ACC1 ACC0
Write
相關(guān)PDF資料
PDF描述
MCZ33976EG Dual Gauge Driver with Configurable esponse Time
MCZ33977EG Single Gauge Driver
MCZ33989EG System Basis Chip with High-Speed CAN Transceiver
MCZ33990EF Enhanced Class B Serial Transceiver
MCZ33991EG Gauge Driver Integrated Circuit
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
MCZ33970EG 制造商:Freescale Semiconductor 功能描述:IC STEPPER MOTOR GAUGE DRIVER SPI
MCZ33970EGR2 功能描述:馬達(dá)/運動/點火控制器和驅(qū)動器 DUAL GAGE DRVR IMP DAMP RoHS:否 制造商:STMicroelectronics 產(chǎn)品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
MCZ33972AEK 功能描述:接口 - 專用 MULT SW DET SUP-WKUP RoHS:否 制造商:Texas Instruments 產(chǎn)品類型:1080p60 Image Sensor Receiver 工作電源電壓:1.8 V 電源電流:89 mA 最大功率耗散: 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:BGA-59
MCZ33972AEK/R2 制造商:FREESCALE 制造商全稱:Freescale Semiconductor, Inc 功能描述:Multiple Switch Detection Interface with Suppressed Wake-up
MCZ33972AEKR2 功能描述:接口 - 專用 MULT SW DET SUP-WKUP RoHS:否 制造商:Texas Instruments 產(chǎn)品類型:1080p60 Image Sensor Receiver 工作電源電壓:1.8 V 電源電流:89 mA 最大功率耗散: 最大工作溫度:+ 85 C 安裝風(fēng)格:SMD/SMT 封裝 / 箱體:BGA-59