![](http://datasheet.mmic.net.cn/30000/MQ83C154DXXX-25-883R_datasheet_2377229/MQ83C154DXXX-25-883R_288.png)
288
6384E–ATARM–05-Feb-10
AT91SAM9G20
Once this register has been correctly configured, the user must wait for MOSCS field in the
PMC_SR register to be set. This can be done either by polling the status register or by wait-
ing the interrupt line to be raised if the associated interrupt to MOSCS has been enabled in
the PMC_IER register.
Code Example:
write_register(CKGR_MOR,0x00000701)
Start Up Time = 8 * OSCOUNT / SLCK = 56 Slow Clock Cycles.
So, the main oscillator will be enabled (MOSCS bit set) after 56 Slow Clock Cycles.
2.
Checking the Main Oscillator Frequency (Optional):
In some situations the user may need an accurate measure of the main oscillator frequency.
This measure can be accomplished via the CKGR_MCFR register.
Once the MAINRDY field is set in CKGR_MCFR register, the user may read the MAINF field
in CKGR_MCFR register. This provides the number of main clock cycles within sixteen slow
clock cycles.
3.
Setting PLL A and divider A:
All parameters necessary to configure PLL A and divider A are located in the CKGR_PLLAR
register.
It is important to note that Bit 29 must always be set to 1 when programming the
CKGR_PLLAR register.
The DIVA field is used to control the divider A itself. The user can program a value between
0 and 255. Divider A output is divider A input divided by DIVA. By default, DIVA parameter is
set to 0 which means that divider A is turned off.
The OUTA field is used to select the PLL A output frequency range.
The MULA field is the PLL A multiplier factor. This parameter can be programmed between
0 and 254. If MULA is set to 0, PLL A will be turned off. Otherwise PLL A output frequency is
PLL A input frequency multiplied by (MULA + 1).
The PLLACOUNT field specifies the number of slow clock cycles before LOCKA bit is set in
the PMC_SR register after CKGR_PLLAR register has been written.
Once CKGR_PLLAR register has been written, the user is obliged to wait for the LOCKA bit
to be set in the PMC_SR register. This can be done either by polling the status register or by
waiting the interrupt line to be raised if the associated interrupt to LOCKA has been enabled
in the PMC_IER register.
All parameters in CKGR_PLLAR can be programmed in a single write operation. If at some
stage one of the following parameters, MULA, DIVA is modified, LOCKA bit will go low to
indicate that PLL A is not ready yet. When PLL A is locked, LOCKA will be set again. User
has to wait for LOCKA bit to be set before using the PLL A output clock.
Code Example:
write_register(CKGR_PLLAR,0x20030602)