參數(shù)資料
型號: XRT91L32IQ-F
廠商: EXAR CORP
元件分類: 數(shù)字傳輸電路
英文描述: STS-12/STM-4 OR STS-3/STM-1 SONET/SDH TRANSCEIVER
中文描述: TRANSCEIVER, PQFP100
封裝: 14 X 20 MM, 2.70 MM HEIGHT, PLASTIC, QFP-100
文件頁數(shù): 16/37頁
文件大?。?/td> 417K
代理商: XRT91L32IQ-F
XRT91L32
STS-12/STM-4 OR STS-3/STM-1 SONET/SDH TRANSCEIVER
xr
REV. 1.0.2
14
2.3
The clock and data recovery (CDR) unit accepts the high speed NRZ serial data from the Differential LVPECL
receiver and generates a clock that is the same frequency as the incoming data. The clock recovery can either
utilize the transmitter’s CMU reference clock from either REFCLKP/N or TTLREFCLK or it can use
independent clock source CDRAUXREFCLK to train and monitor its clock recovery PLL. Initially upon startup,
the PLL locks to the local reference clock within ±500 ppm. Once this is achieved, the PLL then attempts to
lock onto the incoming receive data stream. Whenever the recovered clock frequency deviates from the local
reference clock frequency by more than approximately ±500 ppm, the clock recovery PLL will switch and lock
back onto the local reference clock. Whenever a Loss of Lock or a Loss of Signal event occurs, the CDR will
continue to supply a receive clock (based on the local reference) to the framer/mapper device. When the
LOSEXT is asserted by the optical module or when LOS is detected, the receive parallel data output will be
forced to a logic zero state for the entire duration that a LOS condition is detected. This acts as a receive data
mute upon LOS function to prevent random noise from being misinterpreted as valid incoming data. When the
LOSEXT becomes inactive and the recovered clock is determined to be within ±500 ppm accuracy with respect
to the local reference source and LOS is no longer declared, the clock recovery PLL will switch and lock back
onto the incoming receive data stream. Table 5 shows Clock and Data Recovery reference clock settings.
Table 6 specifies the Clock and Data Recovery Unit performance characteristics.
T
ABLE
5: C
LOCK
D
ATA
R
ECOVERY
UNIT
REFERENCE
CLOCK
SETTINGS
Receive Clock and Data Recovery
1
Requires frequency accuracy better than 20ppm in order for the transmitted data rate frequency to have the necessary
accuracy required for SONET systems.
2
CDRAUXREFCLK requires accuracy of 77.76 MHz +/- 500ppm.
CMUFREQSEL CDRREFSEL
STS12/
STS3
REFCLKP/N
1OR
TTLREFCLK
1
F
REQUENCY
(MH
Z
)
CDRAUXREFCLK
2
F
REQUENCY
(MH
Z
)
CDR O
UTPUT
F
REQUENCY
(MH
Z
)
0
0
0
77.76 MHz
not used
155.52
0
0
1
77.76 MHz
not used
622.08
1
0
0
19.44 MHz
not used
155.52
1
0
1
19.44 MHz
not used
622.08
X
1
0
not referenced by CDR
77.76 MHz
155.52
X
1
1
not referenced by CDR
77.76 MHz
622.08
相關(guān)PDF資料
PDF描述
XRT91L80 2.488/2.666 GBPS STS-48/STM-16 SONET/SDH TRANSCEIVER
XRT91L80_0507 2.488/2.666 GBPS STS-48/STM-16 SONET/SDH TRANSCEIVER
XRT91L80IB 2.488/2.666 GBPS STS-48/STM-16 SONET/SDH TRANSCEIVER
XRT91L81 2.488/2.666GBPS OC-48/STM-16 SONET/SDH TRANSCEIVER
XRT91L81IB 2.488/2.666GBPS OC-48/STM-16 SONET/SDH TRANSCEIVER
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
XRT91L32IQTR 功能描述:LIN 收發(fā)器 PHY Transceiver RoHS:否 制造商:NXP Semiconductors 工作電源電壓: 電源電流: 最大工作溫度: 封裝 / 箱體:SO-8
XRT91L32IQTR-F 功能描述:LIN 收發(fā)器 PHY Transceiver RoHS:否 制造商:NXP Semiconductors 工作電源電壓: 電源電流: 最大工作溫度: 封裝 / 箱體:SO-8
XRT91L33 制造商:EXAR 制造商全稱:EXAR 功能描述:STS-12/STS-3 MULTIRATE CLOCK AND DATA RECOVERY UNIT
XRT91L33AIG-F 制造商:Exar Corporation 功能描述:CDR 155.52Mbps/622.08Mbps SONET/SDH 20-Pin TSSOP
XRT91L33ES 功能描述:界面開發(fā)工具 Eval System for XRT91L33 Series RoHS:否 制造商:Bourns 產(chǎn)品:Evaluation Boards 類型:RS-485 工具用于評估:ADM3485E 接口類型:RS-485 工作電源電壓:3.3 V