208
CHAPTER 13 SERIAL INTERFACE CHANNEL 0
(1) Serial I/O shift register 0 (SIO0)
This is an 8-bit register to carry out parallel/serial conversion and to carry out serial transmission/reception
(shift operation) in synchronization with the serial clock.
SIO0 is set with an 8-bit memory manipulation instruction.
When bit 7 (CSIE0) of serial operating mode register 0 (CSIM0) is 1, writing data to SIO0 starts serial operation.
In transmission, data written to SIO0 is output to the serial output (SO0) or serial data bus (SB0/SB1). In
reception, data is read from the serial input (SI0) or SB0/SB1 to SIO0.
Note that, if a bus is driven in the SBI mode or 2-wire serial I/O mode, the bus pin must serve for both input
and output. Thus, in the case of a device for reception, write FFH to SIO0 in advance (except when address
reception is carried out by setting bit 5 (WUP) of CSIM0 to 1).
In the SBI mode, the busy state can be cleared by writing data to SIO0. In this case, bit 7 (BSYE) of the serial
bus interface control register (SBIC) is not cleared to 0.
RESET input makes SIO0 undefined.
(2) Slave address register (SVA)
This is an 8-bit register to set the slave address value for connection of a slave device to the serial bus.
SVA is set with an 8-bit memory manipulation instruction. It is not used in the 3-wire serial I/O mode.
The master device outputs a slave address for selection of a particular slave device to the connected slave
device. These two data (the slave address output from the master device and the SVA value) are compared
with an address comparator. If they match, the slave device has been selected. In that case, bit 6 (COI) of
serial operating mode register 0 (CSIM0) becomes 1.
Address can also be compared on the data of LSB-masked high-order 7 bits by setting (1) bit 4 (SVAM) of
the interrupt timing specify register (SINT).
If no matching is detected in address reception, bit 2 (RELD) of the serial bus interface control register (SBIC)
is cleared to 0. In the SBI mode, the wake-up function can be used by setting bit 5 (WUP) of CSIM0 to 1.
In this case, an interrupt request signal (INTCSI0) is generated only when the slave address output by the
master coincides with the value of SVA. This interrupt indicates that the master has issued a request for
communication. While bit 5 (SIC) of the interrupt timing specification register (SINT) is set to 1, the wake-
up function does not operate even if WUP is set to 1 (the interrupt signal is generated when bus release is
detected). Clear SIC to 0 to use the wake-up function.
Further, when SVA transmits data as master or slave device in the SBI or 2-wire serial I/O mode, errors can
be detected by using SVA.
RESET input makes SVA undefined.