ADATE302-02
Rev. A | Page 12 of 58
Parameter
Min
Typ
Max
Unit
Test
Level
Conditions/Comments
AC SPECIFICATIONS
Load active on, unless otherwise noted
Dynamic Performance
Propagation Delay, Load Active On
to Load Active Off; 50%, 90%
4.1
ns
CB
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = 1.25 V for IOH; measured from 50%
point of RCVxP RCVxN to 90% point of final output,
repeat for drive low and high
Propagation Delay, Load Active Off
to Load Active On; 50%, 90%
11
ns
CB
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = 1.25 V for IOH; measured from 50%
point of RCVxP RCVxN to 90% point of final output,
repeat for drive low and high
Propagation Delay Matching
6.9
ns
CB
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = 1.25 V for IOH; active on vs. active
off, repeat for drive low and high
Load Spike
156
mV
CB
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 0 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM = 1.25 V for IOH; repeat for drive low
and high
Settling Time to 90%
1.6
ns
CB
Toggle RCVx pins, DUTx terminated 50 Ω to GND,
IOH = IOL = 12 mA, VH = VL = 0 V, VCOM = +1.25 V for
IOL and VCOM= 1.25 V for IOH; measured at 90% of
final value
PMU
FV = force voltage, MV = measure voltage, FI = force current, MI = measure current, FN = force nothing.
Table 7.
Parameter
Min
Typ
Max
Unit
Test
Level
Conditions/Comments
FORCE VOLTAGE (FV)
Current Range A
±25
mA
D
Current Range B
±2
mA
D
Current Range C
±200
μA
D
Current Range D
±20
μA
D
Current Range E
±2
μA
D
Force Input Voltage Range at
Output For All Ranges
2.0
+6.0
V
D
Force Voltage Uncalibrated
Accuracy for Range C
100
±25
+100
mV
P
PMU enabled, FV, PE disabled, error measured at calibration
points of 0 V and 5 V
Force Voltage Uncalibrated
Accuracy for All Ranges
±25
mV
CT
PMU enabled, FV, PE disabled, error measured at calibration
points of 0 V and 5 V; repeat for each PMU current range
Force Voltage Offset Tempco
for All Ranges
±25
μV/°C
CT
Measured at calibration points for each PMU current range
Force Voltage Gain Tempco
for All Ranges
±75
ppm/°C
CT
Measured at calibration points for each PMU current range
Forced Voltage INL
7
±2
+7
mV
P
PMU enabled, FV, Range C, PE disabled, after two-point gain/
offset calibration; measured over output range of 2.0 V to
+6.0 V
Force Voltage Compliance vs.
Current Load
PMU enabled, FV, PE disabled, force 2.0 V, measure voltage
while PMU sinking zero- and full-scale current; measure ΔV;
force 6.0 V, measure voltage while PMU sourcing zero- and full-
scale current; measure ΔV; repeat for each PMU current range
Range A
±4
mV
CT
Range B to Range E
±1
mV
CT