Absolute Maximum Ratings
Storage Temperature, Plastic Packages. . . . . . . . . . . . . . . . –65°C to +150°C
Ambient Temperature with Power Applied . . . . . . . . . . . . . . –65°C to +125°C
Voltage with Respect to Ground:
All Inputs and I/Os except as noted below (Note 1) . . . . –0.5 V to VIO + 0.5 V
VCC (Note 1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +2.5 V
VIO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .–0.5 V to +3.5 V
ACC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to +12.5 V
Output Short Circuit Current (Note 3)100 mA
Notes:
1. Minimum DC voltage on input or I/Os is –0.5 V. During voltage transitions, inputs
or I/Os may undershoot VSS to –2.0 V for periods of up to 20 ns during voltage
transitions inputs might overshoot to VCC +0.5 V for periods up to 20 ns. See
Figure 6. Maximum DC voltage on input or I/Os is VCC + 0.5 V. During voltage transitions outputs may overshoot to VCC + 2.0 V for periods up to 20 ns. See
2. No more than one output may be shorted to ground at a time. Duration of the
short circuit should not be greater than one second.
3. Stresses above those listed under “Absolute Maximum Ratings” may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
sections of this data sheet is not implied. Exposure of the device to absolute max-
imum rating conditions for extended periods may affect device reliability.
Operating Ranges
Industrial (I) Devices
Ambient Temperature (TA) . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to +85°C
Supply Voltages
VCC Supply Voltages. . . . . . . . . . . . . . . . . . . . . . . . . . . .+1.65 V to +1.95 V
VIO Supply Voltages:
VIO ≤ VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +1.65 V to +1.95 V
VIO > VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +2.7 to +3.15 V
Operating ranges define those limits between which the functionality of the device is
guaranteed.
Figure 6. Maximum Negative
Overshoot Waveform
Figure 7. Maximum Positive Overshoot Waveform
20 ns
+0.8 V
–0.5 V
20 ns
–2.0 V
20 ns
VCC
+2.0 V
VCC
+0.5 V
20 ns
2.0 V